LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
F3SJ-A1271P14 | OMRON Safety Light Curtain F3SJ-A1271P14
OMRON F3SJ-A1271P14 Manual And Instructions
F3SJ-A1271P14 datasheetPDF datasheet
F3SJ-A1271P14 Installation and Operating Manual
F3SJ-A1271P14 INSTRUCTION sheet

OMRON F3SJ-A1271P14 Product information and technical parameters:
Brand: OMRON
Name: Safety Light Curtain
Model: F3SJ-A1271P14
Number of beams: 140.
Protective height: 1271mm.
Model: PNP output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions.

Actuator: Roller plunger (Metal roller).
Cable length: 1 m.
Pull-outing direction of cable: Horizontal.
Built-in switch: 2NC/2NO (slow-action).
Smallest Class of Safety Limit Switches the World.
The world''s smallest limit switch with a direct opening,
mechanism (four-contact construction model) OMRON F3SJ-A1271P14.
High-sensitivity safety limit switch.
Built-in switches with two- or four-contact construction are available F3SJ-A1271P14
Degree of protection: IP67.
Conforms to EN115-1, EN81-1 and EN81-2.
(slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Actuator: Shaft.
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action).
Compact, Plastic-body Safety-door OMRON F3SJ-A1271P14.
Hinge Switch Designed for Saving.
Space in Machines and Other.
Equipment.
Lineup includes three contact models with 2NC/1NO and.
3NC contact forms in addition to the previous contact forms.
1NC/1NO, and 2NC. Models with MBB contacts are also available.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads. The type of the drive lever: one way action roller rocker type (horizontal action) OMRON F3SJ-A1271P14.
Conduit size: single catheter type, M20.
Built in switch structure: slow motion (1NC).
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC).
Forced open action structure.
The slow moving contact structure is adopted to ensure that the contact distance is 4mm.
Elevator and escalator can be used. Name: Safety I/O Terminals.
No. of I/O points: Safety inputs: 4, safety outputs (relay): 4, test outputs: 4.
Distributed Safety Terminals That.
Reduce Wiring.
Lineupp includes four models to accommodate various,
I/O types and number of I/O points F3SJ-A1271P14.
Monitor the safety system from Standard Controllers,
across the network.
EN954-1 (Cat.4), ISO13849-1 (PLe),
and IEC 61508 SIL3 certification.
The DST1-XD0808SL-1 also supports logic operation,
functions for high-speed processing in applications,
requiring partial stopping of the safety system F3SJ-A1271P14.