LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
G79-Y300C | OMRON Connector cable for I/O relay terminal G79-Y300C

OMRON G79-Y300C Product information and technical parameters:
Brand: OMRON
Name: Connector cable for I/O relay terminal
Model: G79-Y300C
Cable /G79-Y_C with loose wire connecting terminal.
L size: 3000mm.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable.

Cable Specifications: Fire-retardant, Robot cable.
Cable connection direction: Straight.
Cable diameter: 6.0 mm dia.
No. of cable cores: 3.
Cable core cross sectional area: 0.5 mm.
Cable length: 5 m.
DC.
Minimum order: 5.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort OMRON G79-Y300C.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating G79-Y300C
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified OMRON G79-Y300C.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase OMRON G79-Y300C.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Power rating: 100 W.
Input voltage: 100 to 120 VAC, 200 to 240 VAC (allowable range: 85 to 132 VAC,
176 to 264 VAC, or 248 to 373 VDC(Select with the switch.).
Output voltage: 36 V VDC.
Output current: 2.8 A.
Built-in fan: None.
Model with terminal block facing forward.
High Reliability at a Reasonable Cost.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage.
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life. A reliable 3-year warranty G79-Y300C.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications.
Global Standards: Conforms to CE (all models),
Approved foor UL (all models) and CCC (15 to 150-W models) G79-Y300C.
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W.


...More relevant models >>>>
Last one: OMRON G79-Y200C