LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
G9H-210S-US DC24 | OMRON Hybrid Power Relay G9H-210S-US DC24
OMRON G9H-210S-US DC24 Manual And Instructions
G9H-210S-US DC24 datasheetPDF datasheet

OMRON G9H-210S-US DC24 Product information and technical parameters:
Brand: OMRON
Name: Hybrid Power Relay
Model: G9H-210S-US DC24
Isolation method: Relay.
Zero cross function: No.
Operation indicator: Yes.
Applicable output load(See note.): 10 A 100 to 240 VAC.
Rated input voltage: 24 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations.
Relays contacts for power ON and 10-A switching with high,
capacity are provided in a compact body without the need of,
radiators. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation.
Built-in temperature fuse prevents internal burning due to,
triac or relay malfunctions.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays.

Insulation mode: three end two-way switch coupler.
Zero trigger function: No.
Action indicator: there.
Applicable load of output: AC5 240V ~ DC5 1.0A ~ 100V.
Input rated voltage: DC24V.
With the same shape of the power FET MOS G2R relay AC/DC dual, can achieve 1A load switching performance.
Can achieve AC240V or DC100V, 1A load switch OMRON G9H-210S-US DC24.
Output open circuit leakage current: 10 A G9H-210S-US DC24
Input / output voltage resistance AC2500V.
Built in input resistance and over voltage absorbing circuit.
Can be carried out AC full wave rectifier load, half wave rectifier load switch.
Classification: Models with built-in diodes.
Rated voltage: Standard products, 12, 24, or 100/110 VDC;
Made-to-order items, 48 VDC OMRON G9H-210S-US DC24.
New Latching Levers for Circuit Checking.
Added to Our Best-selling.
MY General-purpose Relays.
Now lead-free to protect the environment.
VDE certification (Germany).
Different colors of coil tape for AC and,
DC models to more easily distinguish them.
MY(S) models with latching levers added for,
easier circuit checking. Number of phases: Three-phase.
Insulation method: Phototriac coupler OMRON G9H-210S-US DC24.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: Externally attached heat sinks.
Applicable load: 35 A, 200 to 480 VAC.
Number of pole: 3.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work.
with DIN Track Mounting.
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification). Structure: Relays with PCB Terminals.
Classification: Standard models Compliance with Electrical,
Appliances and Material Safety Act.
Number of poles: 1.
Power-switching Compact.
General-purpose Relays.
The standard models include models that are,
compliant with the UL, CSA, and SEV safety.
standards and with the Electrical Appliances and,
Material Safety Act.
Equipped with an arc barrier for arc interruption.
Withstand voltages up to 2,000 V.
New built-in diode and built-in CR circuit models have,
joined the series.
The lineup alsoo includes models that are compliant,
with the LR and VDE safety standards G9H-210S-US DC24.
Single-pole and double-pole models have AC4,
ratings and DC2 ratings (operating coil ratings:
100/110 VAC, 110/120 VAC, 200/220 VAC, 220/240 VAC,
and 1100/110 VDC) G9H-210S-US DC24.
Three-pole and four-pole models have AC4 ratings,
and DC2 ratings (operating coil ratings: 100/110,
VAC, 200/220 VAC and 100/110 VDC).


...More relevant models >>>>