Operation/resetting system: Time-limit operation/self-resetting.
Operation mode: ON-delay operation.
Terminal: 8-pin round socket.
Time-limit contact: SPDT.
Instantaneous contact: SPDT.
Mounting: Surface mounting/track mounting; Flush mounting.
DIN-sized (48 x 48, 45 x 75 mm) Timer with.
Digital Setting and LCD Display.
Dual power supplies for free AC/DC.
Eight operation modes selectable with one unit.
seconds to 9,990 hrs.
Four external signal inputs.
remaining time.
Conforms to UL, CSA, and CE marking.
Operating modes: Flicker ON start.
Supply voltage: 100 to 240 VAC/100 to 125 VDC, 24 to 48 VAC/12 to 48 VDC.
0.05 s to 300 h models: 8-pin models.
DIN 48 × 48-mm Twin Timers.
Wide power supply ranges of High Voltage 100 to 240 VAC/100,
to 125 VDC and Low Voltage 24 to 48 VAC/12 to 48 VDC.
ON- and OFF-times can be set independently and so,
combinations of long ON- or OFF-time and short OFF- or ON,
time settings are possible OMRON H3CA-8H
H3CA-8H
Twenty-four time ranges from 0.05 s to 300 h depending on the,
model to be used.
Models with a flicker ON start or flicker OFF start are available.
Easy sequence checks through instantaneous outputs for a,
zero set value at any time range.
Length, when panel-mounted with a Socket, of 80 mm or less OMRON H3CA-8H .
11-pin and 8-pin models are available. Count input: PNP/NPN universal DC voltage input (4.5 to 30 VDC).
Display: 7-segment LCD.
Max. revolutions displayed (applicable encoder resolution):
1000 s–1 (1 pulse/rev.), 1000 min–1 (60 pulse/rev.); Light-gray body.
Revolutions displayed up to five digits.
Dual revolution display according to encoder resolution used;
1000 s–1/1000 min–1 or 1000 OMRON H3CA-8H . 0 s–1 /1000.0 min–1,
Switchable dual revolution display type available (-NV1 models);
extended up to 10000 min–1. Supply voltage: 24 to 230 VAC (50/60Hz)/24 to 48 VDC.
Control output: Contact output: SPDT (time-limit output SPDT).
Input type: No-input available.
Operating mode(see note): Eight multi-modes: Four multi-modes: A, B2, E, J.
Model: Screw terminal type.
Eight operating modes (H3DS-M) and four operating modes,
(H3DS-S) cover a wide range of applications.
A wide time setting range of 0.10 s to 120 h.
Two LEDs indicate power and relay status respectively. Type of input: AC current input.
Output type: no output.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, meeasurement and display, identification of the panel table H3CA-8H .
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input cann be applied to a variety of measurement and identification situations H3CA-8H .
Series of DeviceNet type.
The depth (panel below) is only short size 95mm.
UL