K2CM-2LA | OMRON Motor Protective Relay K2CM-2LA
OMRON K2CM-2LA Manual And Instructions
K2CM-2LA datasheetPDF datasheet
K2CM-2LA Communications Manual

OMRON K2CM-2LA Product information and technical parameters:
Brand: OMRON
Name: Motor Protective Relay
Model: K2CM-2LA
Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.

Power ratings: 120 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*3).
Output voltage: 24 V.
Output current: 5 A.
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for OMRON K2CM-2LA.
Easy System Commissioning.
New 90-W models with indication monitor that K2CM-2LA
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC OMRON K2CM-2LA.
(Not compliant with EC Directives and other safety standards.) Sensor type: 3 wire DC / DC (PNP) - the 2 wire 1.
Input points: 4.
The I/O sensor connector for centralized wiring,
And the province of the number of processes, strong environmental resistance as the goal,
The outer control relay box.
Compact and strong centralized wiring trunk box conforming to IP67 OMRON K2CM-2LA.
The corresponding sensing I/O connector mode proximity switch, limit switch,
Photoelectric switch.
With the power to show LED, action shows LED.
The installation dimensions are the same and are not related to the number of input points,
Therefore, the addition of a simple exchange.
A series of sensors with self diagnostic features are added to the product. Model: PYF (front-mounting), page 14.
Approx: 49 g.
Number of pins: 14 pins.
A Wide Variety of Square and,
Round Sockets in Front-mounting,
and Back-mounting Models,
Models available with finger protection.
Hold-down Clips and Socket Bridges for PYF Sockets,
are also available.
New screwless models available. Rated input (See note 2.): 3-phase 3-wire mode, 3-phase 4-wire mode;
200, 220, 230, 240 VAC, 115, 127, 133, 138 VAC.
Ideal for monitoring 3-phase power supplies.
for industrial facilities and equipment.
Monitor overvoltages and undervooltages for three-phase 3-wire,
or 4-wire power supplies K2CM-2LA.
DIP switch setting for 3-phase 3-wire or 3-phase 4-wire power supply.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Separate outputs possible for overvoltages and undeervoltages K2CM-2LA.
World-wide power specifications supported by one Unit,
(switchable using DIP switch).
Relay status can be monitored using LED indicator.