Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
rent, open-phase, and reverse-phase.
ing the test button.
is indicated from the start of operation.
Space-saving, integrated construction.
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
No. of digits: 4.
Display color: Red.
Input method: Static.
Logic: Negative.
Display contents: Numerals and units.
A Series of Three- to Five-digit Digital.
Display Units with a Character Height of,
14 mm. Models available with either red or,
green displays.
Red or green displays with a character height of 14 mm are,
available for a variety of applications and locations OMRON K2CM-2MA.
Miniature design with a 50-mm depth
K2CM-2MA
Incorporating a connector, thus saving wiring effort.
Connecting to OMRON''s PLCs via dedicated PLC cables (sold separately).
Units and minus symbols are displayed (three- and four-digit model only).
Incorporating a zero suppression function.
The power supply can freely change between 12 and 24 VDC OMRON K2CM-2MA.
CE Marking. UL certification approval. Category: incidental cover type.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan).
Capacity: 100W.
Output voltage: 24V.
Output current: 4.5A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function OMRON K2CM-2MA.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)"Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
iis indicated from the start of operation K2CM-2MA.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K2CM-2MA. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.