Control supply voltage: 100 VAC; With voltage fluctuation compensation.
Operating current: 8 to 20 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
an alarm signal.
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
work with both single-phase and three-phase heaters.
alarms due to variations in the supply voltage.
Rated voltage: 200 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.070 A; 60 Hz, 0.060 A .
Rated input: 50 Hz, 13 W ; 60 Hz, 11 W .
Rated rotational speed: 50 Hz, 2550 r/min; 60 Hz, 3050 r/min.
Maximum flow rate: 50 Hz, 0.9 m3/min; 60 Hz, 1 OMRON K2CU-F20A-CGS. 0 m3/min.
Maximum static pressure: 50 Hz, 49.0 Pa; 60 Hz, 68.6 Pa
K2CU-F20A-CGS
Noise: 50 Hz, 33 dB; 60 Hz, 36 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series OMRON K2CU-F20A-CGS.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Cable type: Standard Cables.
Type: Cable with Plugs on Both Ends (M12 Straight/RJ45) OMRON K2CU-F20A-CGS.
Cable length: 0.3 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Power supply voltage: 24 VDC *1.
Current consumption: 900 mA max. (input from included AC adapter).
Discharge voltage: ±7 kV.
Discharge method: Variable DC.
Airflow (m3/min.): 1.4 to 2.3 m3/min (typical).
Ionization time *2: 1.2 s (0.8 s with no Filter).
Ion balance *2: ±10 V max.
Amount of generated ozone: 0.01 ppm max.
(measured at a distance of 50 mm from air outlet).
Indicators: High-voltage output lamp: ION (yellow),
Cleaning lamp: CLEANING (orange), Power lamp: POWER (green).
Main functions: Automatic ion balance adjustment, airflow adjustment,
manual ion balance adjustment.
Ambient temperature range: Operating and storage: 0 to 50°C.
(with no icing or condensation).
Ambient humidity range: Operating: 35% to 65%,
storage: 35% to 85% (with no condensation).
Weight (packed state): Approx. 2.0 kg.
Materials: Unit: ABS, Discharger: Tungsten, stand: SPCC K2CU-F20A-CGS.
Accessories: Instruction sheet, AC adapter, warning labels (2 types),
FG connection cable (2 m).
High-speed, High cost performance.
Ionization.
High-speed ionization in only 0.8 seconds.
Built-in sensor controls the ion baalance at all times K2CU-F20A-CGS.
Fully open structure makes it possible to perform.
maintenance simply and safely.
Can easily be attached to aluminum profiles.