Control supply voltage: 100 VAC; With voltage fluctuation compensation.
Operating current: 16 to 40 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
an alarm signal.
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
work with both single-phase and three-phase heaters.
alarms due to variations in the supply voltage.
Static type reverse electric relay K2WR type.
Reverse power relay for household and marine generator.
A high precision power detection can be performed by the analog time division multiplier.
Through the rated voltage of the switch, adjust the current simulation of variable,
Can correspond to the rated value of all generators OMRON K2CU-F40A-C.
Due to the instant start in contact, the response difference is minimal,
Position detection with high accuracy
K2CU-F40A-C Sharing with voltage input, no need to control the power supply.
Because it is static, so the anti vibration impact ability, action stability.
Equipped with easy to manage and maintain the boot display with LED. Control supply voltage: 110 VAC; With voltage fluctuation compensation OMRON K2CU-F40A-C.
Operating current: 4 to 10 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out OMRON K2CU-F40A-C.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Power ratings: 180 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*3).
Output voltage: 24 V.
Output current: 7.5 A.
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 OOutput standards K2CU-F40A-C.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) K2CU-F40A-C.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)