LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
K3GN-NLC DC24V | OMRON 1/32 DIN Digital Panel Meter K3GN-NLC DC24V
OMRON K3GN-NLC DC24V Manual And Instructions
K3GN-NLC DC24V datasheetPDF datasheet

OMRON K3GN-NLC DC24V Product information and technical parameters:
Brand: OMRON
Name: 1/32 DIN Digital Panel Meter
Model: K3GN-NLC DC24V
Supply voltage: 24 VDC.
Input type: DC voltage, DC current, or PNP input.
Output type: Judgement output, 2 relay contact outputs (SPST-NO);
Data transmission output, None.
1/32 DIN Digital Panel Meter for Downsizing.
Equipment and Control Panels.
Compact size: 48 x 24 x 82 (W x H x D).
Multi-input compatible: DC voltage/current, rotary pulse.
Two display colors (switchable): green/red.
Selectable outputs.
CE marking and UL/CSA approval.
Splash-proof construction (NEMA4X: equivalent to IP66).

Ultra-slim Timer for G2R Relay Socket.
Pin configuration compatible with G2R Relay and mounts to the,
P2R/P2RF Socket.
Standard multiple time ranges and multiple operating modes.
Conforms to EN61812-1 and IEC60664-1 4 kV/2 for Low Volt,
age, and EMC Directives. Control output: Contact output: DPDT (time-limit output) OMRON K3GN-NLC DC24V.
Supply voltage: 220 VAC (50/60 Hz).
11-pin models.
Solid-state Timer with Valuable Multiple-time K3GN-NLC DC24V
Ranges and Multiple-operating Modes.
Handles a wide range of applications through eight operating modes.
With H3BA-N8H models, the output type can be switched.
between time-limit DPDT and time-limit SPDT + instantaneous.
SPDT using a selector.
Setting rings (order separately) to enable consistent settings OMRON K3GN-NLC DC24V.
and to limit the setting range.
Panel Covers (order separately) to enable various panel.
designs.
CE marking.
UL, CSA and CCC certification, conforms to LR. Classification: Preset Counter.
Input signal system (Count & reset inputs): Contact, Transistor.
Mounting method: Flush mounting, surface mounting.
Display: 7-segment LEDs (10 mm high), Up indicator OMRON K3GN-NLC DC24V.
Number of digits: 4 digits (0 to 9,999).
Backup power for memory protection: Yes (100 to 240 VAC only).
Control output: Contact (SPDT).
Operating mode: Up counting.
Max.counting speed: 5 kcps (see note 1.).
All Required Counter Functions.
Incorporated in a Compact DIN-sized.
(48 × 48) Housing.
In addition to Up and Down models, a reversible (Up-Down),
counter is also available.
Maximum counting speed of 5,000 cps, never before attained by,
a small-size preset counter.
Power supply freely selectable within a range of 100 to 240 VAC.
Also, power supply for the DC-operated models is selectable,
within a range of 12 to 48 V.
Models with memory backup function against power failure available. Unit: CPU Units.
Name: LED type without display (See note 1.).
No. of I/O points: 10.
LCD display: NO.
Power supply voltage: 12 to 24 VDC.
Inputs: 6, 12 to 24 VDC.
Outputs: 4, Transistors.
Buttons, calendar, and clock: NO.
Analog input: Yes.
Even Broader Applications with Increased.
Functionality and Higher Precision.
Increased functionality in a compact body (70 mm wide × 90 mm high).
Easy programming is available using the LCD and operation,
buttons. (See note 1.).
This single Unit easily provides relay, timer, counter, and time,
switch functions.
Expansion is easy with Expansionn I/O Units, allowing up to 44,
I/O points K3GN-NLC DC24V. (See note 2.).
Economy-type and Communications-type CPU Units have been,
added to series.
Improved Weekly Timers (See note 1.).
Increased timing accuracy with a monthly deviation of ±155 s,
max K3GN-NLC DC24V. Multiple-day operation and pulse output operation have,
been added.
Select from two power supply options:
100 to 240 VAC or 12 to 24 VDC.


...More relevant models >>>>