Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
External event input can be applied to a variety of measurement and identification situations.
The depth (panel below) is only short size 95mm.
Supply voltage: 24 to 240 VAC/DC.
Control output: Contact output, SPDT (time-limit SPDT).
Four-mode Timer.
Multiple time ranges and operating modes let you cover a wide,
range of applications.
The time-limit DPDT output contacts can be changed to time-limit,
SPDT and instantaneous SPDT output contacts using a switch OMRON K3HB-XVD-A1 AC100-240.
Sequence checks are easily performed by setting an instanta,
neous output to 0
K3HB-XVD-A1 AC100-240
Start signal control for the H3DK-M. Count input: PNP/NPN universal DC voltage input (4.5 to 30 VDC).
Display: 7-segment LCD.
Max. revolutions displayed (applicable encoder resolution):
1000.0 s–1 (10 pulse/rev.), 1000.0 min–1 (600 pulse/rev.),
←→10000 min–1 (60 pulse/rev.) (switchable) OMRON K3HB-XVD-A1 AC100-240. ; Light-gray body.
Revolutions displayed up to five digits.
Dual revolution display according to encoder resolution used;
1000 s–1/1000 min–1 or 1000.0 s–1 /1000.0 min–1,
Switchable dual revolution display type available (-NV1 models);
extended up to 10000 min–1. Input type: DC voltage input type.
Output type: communication; RS-232C; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with OMRON K3HB-XVD-A1 AC100-240.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DevClassification: Preset Counter.
Input signal system (Count & reset inputs): Contact, Transistor.
Mounting method: Flush mounting, surface mounting.
Display: 7-segment LEDs (10 mm high), Up indicator.
Number of digits: 4 digits (0 to 9,999).
Backup power for memory protection: Yes (100 to 240 VAC only).
Control output: Contact (SPDT).
Operating mode: Up counting.
Max.counting speed: 30 cps.
All Required Counter Functions.
Incorporated in a Compact DIN-sized.
(48 × 48) Housing.
In addition to Up and Down modells, a reversible (Up-Down),
counter is also available K3HB-XVD-A1 AC100-240.
Maximum counting speed of 5,000 cps, never before attained by,
a small-size preset counter.
Power supply freely selectable within a range of 100 to 240 VAC.
Also, poweer supply for the DC-operated models is selectable,
within a range of 12 to 48 V K3HB-XVD-A1 AC100-240.
Models with memory backup function against power failure available.