K8AC-H11CT-FLK | OMRON Digital Heater Element Burnout Detector K8AC-H11CT-FLK
OMRON K8AC-H11CT-FLK Manual And Instructions
K8AC-H11CT-FLK datasheetPDF datasheet
K8AC-H11CT-FLK Communications Manual

OMRON K8AC-H11CT-FLK Product information and technical parameters:
Brand: OMRON
Name: Digital Heater Element Burnout Detector
Model: K8AC-H11CT-FLK
Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).

Type: Twin-connector.
Terminal Block: Terminal block with M3.5 screws.
Connector: Flat Cable Connectors*1.
No. of poles: 40.
Simplifies Connector and terminal,
block replacement, and requires less,
in-panel wiring.
Mount to DIN Track or via screws.
MIL Flat Cable Connectors and Multi-pole, Square,
Connectors are standard OMRON K8AC-H11CT-FLK.
Terminal blocks available with either M3 or M3 K8AC-H11CT-FLK5 screws.
Connecting Cables for Programmable Controllers,
available (sold separately). Control power supply voltage: 24 VDC.
Input: DC or AC (selectable), Input voltage range, 0.2 to 12 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V OMRON K8AC-H11CT-FLK.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection OMRON K8AC-H11CT-FLK.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@). Shape: DIP straight terminal.
Pole number: 30.
Pole pole number: 1.
Minimum packing unit: 50.
Printed board connector core, MIL specification standard.
Through the use of new productivity design, high reliability and low price synchronization.
A box type plug (XG4C) which is convenient for saving space is provided in the province.
A press type plug (XG4E) capable of using the relay is provided.
Will be the company''s loose wire connector (XGG5) - specific plug (XG8) and PCB type K8AC-H11CT-FLK.
(XG2) combined use of various types of packaging can be achieved.
Suitable for the company''s own development of a simple locking lever can make the unique plug (XG8) and,
Box type plugs (XG4C) can also be locked K8AC-H11CT-FLK.
MIL specification (MIL-C-83503) standard.
Standard product conforms to the UL specification (No. E103202 File) certified products.