Structure: Relays with Plug-in Terminals.
absorption (DC coil specification only).
Number of poles: 1.
Power-switching Compact.
General-purpose Relays.
compliant with the UL, CSA, and SEV safety.
Material Safety Act.
Equipped with an arc barrier for arc interruption.
Withstand voltages up to 2,000 V.
joined the series.
with the LR and VDE safety standards.
and 100/110 VDC).
VAC, 200/220 VAC and 100/110 VDC).
Number of elements: 3.
Isolation method: Phototriac coupler.
Rated powersupply voltage: 12 to 24 VDC.
Input method: No-voltage input (open and short circuited input).
Applicable monitor capacity (AC3): 2.2 kW (11.1 A), 200 to 220 VAC.
Monitor output: DC switching output.
New Models with AC Power Supply Input and,
Monitor Output Equivalent to Non-contact,
SPST-NO Join the G3J-T Series,
Limiting the starting current saves energy OMRON LY1-D
LY1-D
Certified for UL and CSA.
Mounts with screws or to DIN Track.
Compact design with heat sinks (3.7-kW models: 100 × 100 ×130 mm (W × H × D)).
Built-in snubber circuit and thyristor.
Built-in operation indicator. Classification: Models with built-in diodes OMRON LY1-D.
Rated voltage: Standard products, 12, 24, or 100/110 VDC;
Made-to-order items, 48 VDC.
New Latching Levers for Circuit Checking.
Added to Our Best-selling.
MY General-purpose Relays.
Now lead-free to protect the environment.
VDE certification (Germany).
Different colors of coil tape for AC and,
DC models to more easily distinguish them.
MY(S) models with latching levers added for,
easier circuit checking OMRON LY1-D. Number of elements: 3.
Isolation method: Phototriac coupler.
Rated powersupply voltage: 12 to 24 VDC.
Input method: No-voltage input (open and short circuited input).
Applicable monitor capacity (AC3): 0.75 kW (4.8 A), 200 to 220 VAC.
Monitor output: DC switching output.
New Models with AC Power Supply Input and,
Monitor Output Equivalent to Non-contact,
SPST-NO Join the G3J-T Series,
Limiting the starting current saves energy.
Certified for UL and CSA.
Mounts with screws or to DIN Track.
Compact design with heat sinks (3.7-kW models: 100 × 100 ×130 mm (W × H × D)).
Built-in snubber circuit and thyristor.
Built-in operation indicator. Structure: Relays with PCB Terminals.
Classification: Standard models Compliance with Electrical,
Appliances and Material Safety Act.
Number of poles: 2.
Power-switching Compact.
General-purpose Relays.
The standard models include models that are,
compliant with the UL, CSA, and SEV safety.
standards and with the Electrical Appliances and,
Material Safety Act.
Equipped with an arc barrier for arc interruption.
Withstand voltages up to 2,000 V.
New built-in diode and built-in CR circuit models have,
joined the series.
The lineup also includes models that are compliant,
with the LR and VDE safety standards LY1-D.
Single-pole and double-pole models have AC4,
ratings and DC2 ratings (operating coil ratings:
100/110 VAC, 110/120 VAC, 200/220 VAC, 220/240 VAC,
and 1100/110 VDC) LY1-D.
Three-pole and four-pole models have AC4 ratings,
and DC2 ratings (operating coil ratings: 100/110,
VAC, 200/220 VAC and 100/110 VDC).