Structure: Relays with PCB Terminals.
Appliances and Material Safety Act.
Number of poles: 2 Bifurcated.
Power-switching Compact.
General-purpose Relays.
compliant with the UL, CSA, and SEV safety.
Material Safety Act.
Equipped with an arc barrier for arc interruption.
Withstand voltages up to 2,000 V.
joined the series.
with the LR and VDE safety standards.
and 100/110 VDC).
VAC, 200/220 VAC and 100/110 VDC).
Control terminal block: Screwless clamp terminal block.
Type: Standard.
Capacity: 45 A, 100 to 240 VAC.
Heater burnout detection: No.
Communications: No.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control OMRON LY2Z-0.
RS-485 communications to set manipulated variables and,
monitor load current
LY2Z-0
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,
and constant-current control.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified OMRON LY2Z-0. Classification: Models with built-in CR circuits and operation indicators.
Rated voltage: Standard products, 100/110 or 200/220 VAC;
Made-to-order items, 110/120 or 220/240 VAC.
New Latching Levers for Circuit Checking.
Added to Our Best-selling.
MY General-purpose Relays.
Now lead-free to protect the environment.
VDE certification (Germany).
Different colors of coil tape for AC and,
DC models to more easily distinguish them OMRON LY2Z-0.
MY(S) models with latching levers added for,
easier circuit checking. Number of elements: 3.
Insulation method: Phototriac.
Rated supply voltage: 12 to 24 VDC.
Input method: No-voltage input (open and short circuit input).
Applicable motor: 0.75 kW (4.8 A), 200 to 220 VAC.
Soft-start/stop Function Starts and Stops.
Three-phase Motors Smoothly and.
Economically.
Function like an inverter by holding down the starting current.
Comply with UL, CSA, IEC (400-V models only), and JEM.
requirements.
Mount with screws or to DIN tracks.
Compact monoblock construction for the G3J-T217BL.
(W: 100 × H: 100 × D: 110 mm) with a heat sink.
Snubber circuit and varistor are built-in.
Operation indicator. Name: Multi-channel Power Controller.
Number of control channels: 4.
Heater burnout detection: Not supported.
Load power supply voltage: 100 to 240 VAC.
Optimum Cycle Control for High-precision.
Control with Low Noise.
Smaller than a Normal Power Controller.
Enables low-noise power control in combination with zero-cross.
SSRs. (See note.).
One Controller can control up to 8 SSRs.
RS-485 communications to set manipulated variables and,
heater burnout detecttion LY2Z-0. The Smart FB Library for the G3ZA,
can also be used.
CE Marking.
Main Upgraded Functions.
Soft-start function added for lamp heaters.
Three-phase optimum cycle control added for three-phase heaters.
Combining with special CT for1550-A current detection LY2Z-0.
Note: The G3ZA must be used in combination with an SSR without the,