Type: Standard.
Contact form: DPDT.
Open structure: Screw terminals.
Mechanically Latching Relays Based on the.
MM Power Relay.
Low power consumption due to mechanical latch for economic operation.
(e.g., AC setcoil and DC reset coil).
Operational response fast enough to enable pulse signal power applications.
Ambient operating temperature: –10°C to 55°C.
Type: Standard.
Contact form: 4PDT.
Open structure: Solder terminals.
Mechanically Latching Relays Based on the.
MM Power Relay.
Low power consumption due to mechanical latch for economic operation.
Relays with mixed coil specifications can be produced,
(e.g., AC setcoil and DC reset coil).
Operational response fast enough to enable pulse signal power applications OMRON MM2KB.
Ambient operating temperature: –10°C to 55°C
MM2KB Isolation: Phototriac.
Zero cross function: No.
Indicator: No.
Rated output load: 20 A at 100 to 240 VAC.
Rated input voltage(See note 1, 2.): 5VDC, 12VDC, 24VDC.
Compact, Low-cost, SSR Switching 5 to 20 A.
Wide load voltage range: 75 to 264 VAC. Both 100-V and,
200-V loads can be handled with the same model OMRON MM2KB.
Dedicated, compact aluminum PCB and power elements used.
Built-in varistor effectively absorbs external surges.
Quick-connect #110 input terminals and #250 output,
connections. (#187 input terminals and #250 output,
connections are available.).
“-US” models certified by UL, CSA, and IEC/EN (TÜV). Terminal (Wire connection): Screw terminal.
Classification: Standard OMRON MM2KB.
Latching lever (Test switch): No.
Rated input voltage: AC/DC, 48V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Contact form: SPST-NO/SPST-NC.
Type: Standard Models.
Rated voltage: AC: 24, 100, 110, 120, 200, 220, 230, 240;
DC: 12, 24, 48, 110, 220.
MK-S-series Relays with DC-switching,
Models That Can Switch 220 VDC, 10 A,
(Resistive Load).
Switch a DC load of 220 VDC, 10 A (resistive load).
Models for AC Loads can switch 250 VAC, 15 A (ressistive load) MM2KB.
Lineup includes models with SPST-NO and SPST-NO/SPST,
NC contact forms.
Using a SPST-NO/SPST-NC contact form enables detecting,
contact welding. (When the NO contacts become welded, the,
NC contacts will maintain a minimum distance of 0 MM2KB. 5 mm.).
Models available with operation indicators and built-in test buttons.
RoHS compliant.
Standards: UL, IEC (TÜV certification).