LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
MM2KP | OMRON Latching Relay MM2KP
OMRON MM2KP Manual And Instructions
MM2KP datasheetPDF datasheet

OMRON MM2KP Product information and technical parameters:
Brand: OMRON
Name: Latching Relay
Model: MM2KP
Type: Standard.
Contact form: DPDT.
Cased: Plug-in (octal pins) terminals.
Mechanically Latching Relays Based on the.
MM Power Relay.
Low power consumption due to mechanical latch for economic operation.
Relays with mixed coil specifications can be produced,
(e.g., AC setcoil and DC reset coil).
Operational response fast enough to enable pulse signal power applications.
Ambient operating temperature: –10°C to 55°C.

Classification: Standard models.
Rated voltage: Standard products, 100/110 or 200/220 VAC, 12 or 24 VDC;
Made-to-order items, 12, 24, 100/120, or 200/240 VAC, 48 or 100/110 VDC.
New Latching Levers for Circuit Checking.
Added to Our Best-selling.
MY General-purpose Relays.
Now lead-free to protect the environment OMRON MM2KP.
VDE certification (Germany).
Different colors of coil tape for AC and,
DC models to more easily distinguish them MM2KP
MY(S) models with latching levers added for,
easier circuit checking. Type: DC-switching.
Contact form: DPDT.
Open structure: Screw terminals.
Mechanically Latching Relays Based on the.
MM Power Relay.
Low power consumption due to mechanical latch for economic operation OMRON MM2KP.
Relays with mixed coil specifications can be produced,
(e.g., AC setcoil and DC reset coil).
Operational response fast enough to enable pulse signal power applications.
Ambient operating temperature: –10°C to 55°C. Isolation: Phototriac coupler.
Zero cross function: NO.
Indicator: NO.
Rated output load: 3 A at 100 to 240 VAC *1 .
Rated input voltage: 12 VDC.
New Models with International Standards OMRON MM2KP.
Added to G3H Series (-VD in model number).
Same Profile as LY1 and LY2 Bi-power.
Relays.
Certified by UL, CSA, and VDE (models numbers with a suffix of “-VD”).
Socket type, same size as LY Power Relays.
Operation indicator provided to confirm input,
(models numbers with “N” before the suffix). Standard certification: No.
Insulation: photo coupler.
Zero crossing trigger function.
Action indicator: No.
Applicable load of output: AC100 3A ~ 240V.
Input rated voltage: DC4 ~ 24V.
With the LY1, LY2 large power relay with the same shape of the G3H series, the new international standard certification (-VD type).
Achieved UL, CSA, EN (VDE certification) standard certification. (type -VD)
Socket terminal type of same size with LY (1 pole, 2 pole type).
A model with an action indicator to check the status of the input. (type N)Number of phase: Single-phase.
Control terminal block: Terminal block with small slotted screws.
Type: Constant current.
Capacity: 45 A, 100 to 240 VAC.
Heater burnout detection: Yes.
Communications: Yes.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control MM2KP.
RS-485 communications to set manipulated variables and,
monitor load current.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,,
and constant-current control MM2KP.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified.