Classification: Models with built-in operation indicators.
or 220/240 VAC, 12, 24, 48, or 100/110 VDC; Made-to-order items, --.
New Latching Levers for Circuit Checking.
Added to Our Best-selling.
MY General-purpose Relays.
Now lead-free to protect the environment.
VDE certification (Germany).
DC models to more easily distinguish them.
easier circuit checking.
The main body: with shell type / socket terminal type.
Classification: internal connection special type (contact Ag).
Pole number: 3 pole.
A variety of eight pin pin type electric power.
With shell models have AC4 rated specifications (50/60Hz AC200/220V, 50/60Hz AC100/110V).
Installation, wiring convenient, easy to operate OMRON MY2N AC220/240.
Has more than 5 million mechanical life, durable
MY2N AC220/240
Standard type, with shell type, special contact specifications, double contact type, double coil latch type, etc., the product is complete. Input terminals: Screwless clamp terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection) OMRON MY2N AC220/240.
Applicable load (See note.): 2 to 25 A, 100 to 240 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters OMRON MY2N AC220/240.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable).
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified. Isolation: Phototriac.
Zero cross function: No.
Indicator: No.
Rated output load: 20 A at 100 to 240 VAC.
Rated input voltage(See note 1, 2.): 5VDC, 12VDC, 24VDC.
Compact, Low-cost, SSR Switching 5 to 20 A.
Wide load voltage range: 75 to 264 VAC MY2N AC220/240. Both 100-V and,
200-V loads can be handled with the same model.
Dedicated, compact aluminum PCB and power elements used.
Built-in varistor effectively absorbs external surges.
Quick-connect #110 input terminals andd #250 output,
connections MY2N AC220/240. (#187 input terminals and #250 output,
connections are available.).
“-US” models certified by UL, CSA, and IEC/EN (TÜV).