Classification: Models with built-in CR circuits.
Made-to-order items, 110/120 or 220/240 VAC.
New Latching Levers for Circuit Checking.
Added to Our Best-selling.
MY General-purpose Relays.
Now lead-free to protect the environment.
VDE certification (Germany).
DC models to more easily distinguish them.
easier circuit checking.
Insulation method: Photocoupler.
Operation indicator: Yes (yellow).
Zero cross function: No.
Applicable output load: 150 A, 100 to 240 VAC.
Rated input voltage: 5 to 24 VDC.
High-power, Load-control SSRs with.
High Current of 75 or 150 A and High.
Voltage of 240 or 480 VAC.
RoHS compliant.
Models also available with no zero cross OMRON MY2N-CR AC220/240.
Replaceable power elements.
Conforms to cULus standards and EN standards (TÜV certification)
MY2N-CR AC220/240 Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 10 A at 200 to 480 VAC.
Rated input voltage: 5 to 24 VDC.
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A OMRON MY2N-CR AC220/240.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series.
All models feature the same compact dimensions to provide a,
uniform mounting pitch.
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by TÜV OMRON MY2N-CR AC220/240.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)). Isolation: Phototriac coupler.
Zero cross function: NO.
Indicator: NO.
Rated output load: 3 A at 100 to 240 VAC (See note 1.).
Rated input voltage: 12 VDC.
International Standards for G3F Series,
Same Profile as MY Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”).
Socket type, same size as MY Power Relays.
Operation indicator provided to confirm input.
(model numbers with “N” before the suffix). Input terminals: Screwless clamp terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 25 A, 100 to 240 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phhase heaters MY2N-CR AC220/240.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp termiinals (detachable), or compact slotted,
screw terminals (detachable) MY2N-CR AC220/240.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.