Classification: Models with built-in CR circuits and operation indicators.
Made-to-order items, 110/120 or 220/240 VAC.
New Latching Levers for Circuit Checking.
Added to Our Best-selling.
MY General-purpose Relays.
Now lead-free to protect the environment.
VDE certification (Germany).
DC models to more easily distinguish them.
easier circuit checking.
Item: Basic model.
DPDT: Rated voltage, 24 VAC, 50 VAC, 100/(110) VAC,
200/(220) VAC, 12 VDC, 24 VDC, 100 VDC.
Unique Ratchet Mechanism Assures Positive.
Alternate Transfer/Switching Operation.
Each contact in the double-pole contact mechanism performs.
alternate make-brake operation at each pulse input and is thus OMRON MY2Z AC24.
ideal for alternate operation or transfer/switching operation of a motor
MY2Z AC24
Positive operation is assured due to the unique ratchet mecha nism.
Satisfies dielectric strength of 2,000 VAC.
Low power consumption.
(AC: approx. 6.4 VA; DC: approx. 3.9 W). Contact configuration: Four SPST-NO relays.
Heat sink: No.
Built-in SSRs: G3S-201PL-PD.
Zero cross function: No.
Applicable output load: 0 OMRON MY2Z AC24. 6 A at 75 to 264 VAC(See note 1.).
Rated voltage: 5 VDC, 12 VDC, 24 VDC.
Compact Terminal SSR with 4 Outputs.
Easy-to-use SSR block that combines four compact G3S SSRs,
sockets, and heat sink in one unit.
Easy wiring with separate I/O terminal construction.
LED operation indicator.
Special socket used for easy Relay replacement.
Mounts either on DIN track or with screws OMRON MY2Z AC24. Isolation method: Relay.
Zero cross function: No.
Operation indicator: Yes.
Applicable output load(See note.): 10 A 100 to 240 VAC.
Rated input voltage: 24 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations.
Relays contacts for power ON and 10-A switching with high,
capacity are provided in a compact body without the need of,
radiators. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation.
Built-in temperature fuse prevents internal burning due to,
triac or relay malfunctions.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays. Number of phase: Single-phase.
Control terminal block: Screwless clamp terminal block.
Type: Constant current.
Capacity: 45 A, 100 to 240 VAC.
Heater burnout detection: Yes.
Communications: Yes.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cyclle control MY2Z AC24.
RS-485 communications to set manipulated variables and,
monitor load current.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,,
and constant-current control MY2Z AC24.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified.