LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
R87B-FA1A15LPF | OMRON Box Fan R87B-FA1A15LPF
OMRON R87B-FA1A15LPF Manual And Instructions
R87B-FA1A15LPF datasheetPDF datasheet
R87B-FA1A15LPF Connection Guide

OMRON R87B-FA1A15LPF Product information and technical parameters:
Brand: OMRON
Name: Box Fan
Model: R87B-FA1A15LPF
Rated voltage: 100 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2100 r/min; 60 Hz, 2200 r/min.
Maximum flow rate: 50 Hz, 0.9 m3/min; 60 Hz, 1.0 m3/min.
Maximum static pressure: 50 Hz, 43 Pa; 60 Hz, 42 Pa.
Noise: 50 Hz, 42 dB; 60 Hz, 43 dB.
Weight: Approx. 1120 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting.
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades.

Cable length L: 0.5 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Type: With cable.
No. of poles: 4.
Lock: Rear lock.
Cable length: 0.5 m.
Minimum order: 10.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work OMRON R87B-FA1A15LPF.
A newly developed lock mechanism that is compatible with round M12 connectors R87B-FA1A15LPF
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved. Cable length L: 1.0 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch OMRON R87B-FA1A15LPF. Power ratings: 90 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 3.75 A.
Alarm output *2: --.
UL Class 2 Output standards: Yes.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication OMRON R87B-FA1A15LPF.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation R87B-FA1A15LPF.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeency, basic,
frequency, and load conditions R87B-FA1A15LPF. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,


...More relevant models >>>>