Rated voltage: 115 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2,700 r/min; 60 Hz, 3,100 r/min.
Maximum flow rate: 50 Hz, 1.3 m3/min; 60 Hz, 1.5 m3/min.
Maximum static pressure: 50 Hz, 91 Pa; 60 Hz, 85 Pa.
Noise: 50 Hz, 49 dB; 60 Hz, 52 dB.
Weight: Approx. 1,120 g.
Easy One-step Mounting.
simplify installation work.
convenience in confined spaces.
mounting screws).
Optional Replacement Filter and Vent Attachment.
metal blades.
Model: P2RF (front-mounting), page 9.
Approx: 38 g.
Number of pins: 5 pins.
A Wide Variety of Square and,
Round Sockets in Front-mounting,
and Back-mounting Models,
Models available with finger protection.
Hold-down Clips and Socket Bridges for PYF Sockets,
are also available.
New screwless models available OMRON R87B-FA3A15HPF. Shape: with long lock (with open bottom cover).
Pole number: 10
R87B-FA3A15HPF
Pole pole number: 0.
Minimum packing unit: 90.
Printed board connector core, MIL specification standard.
Through the use of new productivity design, high reliability and low price synchronization.
A box type plug (XG4C) which is convenient for saving space is provided in the province.
A press type plug (XG4E) capable of using the relay is provided OMRON R87B-FA3A15HPF.
Will be the company''s loose wire connector (XG5) - specific plug (XG8) and PCB type.
(XG2) combined use of various types of packaging can be achieved.
Suitable for the company''s own development of a simple locking lever can make the unique plug (XG8) and,
Box type plugs (XG4C) can also be locked.
MIL specification (MIL-C-83503) standard.
Standard product conforms to the UL specification (No OMRON R87B-FA3A15HPF. E103202 File) certified products. Open circuit: voltage, no voltage, DC circuit breaker.
Appearance: R2 shell, also has F4 shell.
Rated current: AC110V.
Rated frequency: 50/60Hz.
Consume VA: action time 5VA below.
Action current adjustment range (zero phase converter primary current):
0.1-0.2-0.3-0.4-0.6A (5 shunt).
Control output: 1C, 1A (voltage output contact);
AC 110V 7.5A cos (AC 250V maximum diameter =0.4 825VA),
5000 times 24V 5A L/R=7ms DC (max 125V 25W time DC) 5000 times.
Relay control output for circuit breaker switching.
Quality: about 0.6kg.
External: Mount Searl N1.5.
High voltage grounding relay AGF type, anti wave interference,
Arc grounding, short circuit capability, higgh reliability R87B-FA3A15HPF.
The anti - interference ability is strong, and can safely correspond to the arc grounding fault.
The grounding relay and the zero phase converter ZCT can be separately used.
(any combination is not more than JIS of thee specified error range, and therefore can be used)
Can carry out fine current adjustment, easy to coordinate R87B-FA3A15HPF.
In all the models set up alarm terminal.