Rated voltage: 115 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2300 r/min; 60 Hz, 2600 r/min.
Maximum flow rate: 50 Hz, 1.6 m3/min; 60 Hz, 1.9 m3/min.
Maximum static pressure: 50 Hz, 41 Pa; 60 Hz, 43 Pa.
Noise: 50 Hz, 44 dB; 60 Hz, 47 dB.
Weight: Approx. 2260 g.
Easy One-step Mounting.
simplify installation work.
convenience in confined spaces.
mounting screws).
Optional Replacement Filter and Vent Attachment.
metal blades.
Shape: L DIP shaped terminal.
Pole number: 60.
Pole pole number: 2.
Minimum packing unit: 30.
Printed board connector core, MIL specification standard.
Through the use of new productivity design, high reliability and low price synchronization.
A box type plug (XG4C) which is convenient for saving space is provided in the province OMRON R87B-TA3A15MPFR2.
A press type plug (XG4E) capable of using the relay is provided
R87B-TA3A15MPFR2
Will be the company''s loose wire connector (XG5) - specific plug (XG8) and PCB type.
(XG2) combined use of various types of packaging can be achieved.
Suitable for the company''s own development of a simple locking lever can make the unique plug (XG8) and,
Box type plugs (XG4C) can also be locked.
MIL specification (MIL-C-83503) standard OMRON R87B-TA3A15MPFR2.
Standard product conforms to the UL specification (No. E103202 File) certified products. Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 2 OMRON R87B-TA3A15MPFR2. 00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). R87F-A_A16H-WR waterproof type AC axial flow fan (T40 * _120, wire type).
Rated voltage: 115V.
Allowable voltage range: 85 to 110% of rated voltage.
Frequency: 50/60Hz.
Rated current: 60Hz--0.175A; 50Hz--0.194A.
Rated input: 50Hz--16W:60Hz--15W.
Rated speed: 50Hz--2690r/min; 60Hz--3040r/min.
Maximum air volume: 60Hz--2.5m3/min; 50Hz--2.3m3/min.
Maximum static pressure: 50Hz--70.9Pa; 60Hz--69.6Pa.
Noise: 50Hz--43dB; 60Hz--46dB.
The axial flow fan with the bestt cooling is realized R87B-TA3A15MPFR2.
The design of low noise, high life and good environmental adaptability is considered.
Bearing with high reliability.
Specification for type 48 and metal blade with resin blade 24.
New waterproof type AC axial fan type R87F-A - A16H-WR,
(protection structure IP65) R87B-TA3A15MPFR2.
Through UL, CSA, VDE safety standards, EN/IEC certification of the aircraft is also very rich.