LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
R87F-A3A83L | OMRON AC Axial Fans R87F-A3A83L
OMRON R87F-A3A83L Manual And Instructions
R87F-A3A83L datasheetPDF datasheet

OMRON R87F-A3A83L Product information and technical parameters:
Brand: OMRON
Name: AC Axial Fans
Model: R87F-A3A83L
Rated voltage: 115 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.055 A; 60 Hz, 0.048 A .
Rated input: 50 Hz, 5 W ; 60 Hz, 4 W .
Rated rotational speed: 50 Hz, 1900 r/min; 60 Hz, 2100 r/min.
Maximum flow rate: 50 Hz, 0.4 m3/min; 60 Hz, 0.5 m3/min.
Maximum static pressure: 50 Hz, 19.5 Pa; 60 Hz, 23.5 Pa.
Noise: 50 Hz, 28 dB; 60 Hz, 30 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics.

Power ratings: 15 W.
Input voltage: Single phase, 100 to 240 VAC, 90 to 350 VDC.
Output Voltage: 5 V.
Output current: 3 A.
Boost Current: 3.6 A.
Reliable and Easy Operation-Worldwide Power Supply.
Resistant in tough environments.
Easy and fast installation.
The most compact class on the market OMRON R87F-A3A83L.
Universal input for worldwide applications:
100 to 240 VAC (85 to 264 VAC).
DC input can be available: 90 to 350 VDC R87F-A3A83L
Possible for 2-phase input usage.
Wide operation temperature range: –40 to 70 °C.
Power Boost function at 120%.
Safety standards:
UL508/60950-1, CSA C22.2 No. 107.1/60950-1.
EN50178, EN60950-1.
Lloyd’s standards, EN60204-1 PELV.
Safety of Power Transformers: EN61558-2-16 OMRON R87F-A3A83L.
ANSI/ISA 12.12.01 (excluding 480-W models).
CSA C22.2 No.213 (excluding 480-W models).
15-W,30-W, and 60-W models conform to.
UL Class 2 output Standards.
EMS: EN 61204-3.
EMI: EN 61204-3 Class B.
Three years Warranty *1. Measuring voltage: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC.
Supply voltage: 24 VAC/DC.
Ideal for voltage monitoring for industrial.
facilities and equipment OMRON R87F-A3A83L.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and,
undervoltages.
Manual resetting and automatically resetting supported by one Relay.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Power ratings: 120 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*3).
Output voltage: 24 V.
Output current: 5 A.
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 OOutput standards R87F-A3A83L.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) R87F-A3A83L.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)


...More relevant models >>>>
Last one: OMRON R87F-A1A83L
next one: OMRON R87F-A4A83L