Rated voltage: 100 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.550 A; 60 Hz, 0.460 A .
Rated input: 50 Hz, 50 W; 60 Hz, 48 W.
Rated rotational speed: 50 Hz, 2650 r/min; 60 Hz, 3100 r/min.
Maximum flow rate: 50 Hz, 4.8 m3/min; 60 Hz, 5.7 m3/min.
Maximum static pressure: 50 Hz, 104 Pa; 60 Hz, 107 Pa.
Noise: 50 Hz, 56 dB; 60 Hz, 58 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
environment.
Shaft supported by ball bearings for highly-reliable operation.
(28 type) included in series.
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
product. Check the information given for available models of Axial fans and,
the information in Characteristics.
Cable type: Standard Cables.
Type: Cable with Plugs on Both Ends (M12 Right-angle/RJ45).
Cable length: 0.3 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Type: DC Bus Line Connector.
Number of Connectors: 1.
DC Backup Block for S8TS Prevents 24-VDC.
Outages Due to Power Interruptions or Failures OMRON R87T-A1A05H.
Supplies 24 VDC for a fixed period of time even during
R87T-A1A05H
AC input outages to considerably improve system reliability.
Block Power Supply Basic Block is connected using a Bus Line.
Connector to achieve a simple system configuration.
Notification of alarms is provided by indications on the main unit.
and alarm signal output.
RoHS-Compliant. Type: Normal wiring OMRON R87T-A1A05H.
Cable length L: 2.0 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Type: open type.
Structure: DIN guide rail mounting type.
Capacity: 150W.
Output voltage: 5V.
Output current: 27A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device OMRON R87T-A1A05H.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3--2 R87T-A1A05H. (except for type 15/30W)
Type: Cable with Connectors on Both Ends,
(one ferrite core provided, 30-dia × 39 mm).
Cable length: 20 m.
The highest level of ionization in its class.
Sensing and variable-AC system provides fast and meeticulous ionization R87T-A1A05H.
Linked Ionizers cover a wide area without causing uneven ionization.
Digital ion display provides simple and reliable settings.