Power supply voltage: 100 to 240 VAC.
Output: Transistor.
Timer function: Yes.
Features: Multi-function with two inputs/one output.
High-speed response of 0.1 ms.
Ideal as a two-input Controller.
Power source for the Sensor can be supplied up to 200 mA.
Ultra-slim body with 30-mm width.
Multi-function model equipped with timer functions also available.
Power ratings: 120 W.
Rated input voltage: 100 to 240 VAC .
(allowable range: 85 to 264 VAC or 90 to 350 VDC).
Rated output voltage: 24 V.
Rated output current: 5 A.
Maximum boost current: 6 A.
A Perfect Fit for Small Control Panels.
Coated PCBs for Better Resistance to Environment.
Connections for Easy Wiring OMRON S3D2-CC .
Operation possible at ambient temperatures from -40 to 70°C.
DC input supported (90 to 350 VDC)
S3D2-CC
Power Boost function at 120%.
Horizontal side-by-side mounting.
Vibration resistance to 5G, and 300-VAC abnormal,
input voltage supported for 1 second.
Complies with EN/IEC 61558-2-16.
UL 508 Listing/UL 1310 Class 2 output standards *1,
ANSl/ISA 12.12.01.
Certification for 3,000 m altitude,
(UL/EN/IEC 60950-1 and EN 50178) OMRON S3D2-CC .
Lloyd’s, DNV GL *2.
Conforms to F47-0706.
Five years Warranty *3. Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 150 W.
Output voltage: 12 V.
Output current: 13 A.
Built-in fan: No OMRON S3D2-CC .
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V).
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 508/60950-1, cUL CSA C22.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
Input conditions: The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.).Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
iis indicated from the start of operation S3D2-CC .
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions S3D2-CC . Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.