LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
S8EX-P10005L | OMRON Switch Mode Power Supply S8EX-P10005L
OMRON S8EX-P10005L Manual And Instructions
S8EX-P10005L datasheetPDF datasheet
S8EX-P10005L EtherNet/IP Connection Guide

OMRON S8EX-P10005L Product information and technical parameters:
Brand: OMRON
Name: Switch Mode Power Supply
Model: S8EX-P10005L
Power ratings: 100 W.
Output voltage: 5 V.
Output current: 20 A.
Boost current: --.
Newly Released High-capacity 240-W Models in S8EX-series Lineup.
Rated Output of 300 W for 200 VAC.
From 170 to 264 VAC.
New 240-W Models.
Lineup of models with 24-, 36-, and 48-VDC output.
voltages.
15-W, 35-W, 50-W, 100-W, and 150-W Models.
Lineup of models with from 5 to 48-VDC output.
voltages.
All Models.
Approved standards:
UL60950-1, cUR CSA C22.2 No. 60950-1, EN 50178,
and EN 60950-1.
Lineup includes open-frame models, models with.
chassis, and models with chassis and covers.
Wide-range power supply: 100 to 240 VAC.
Complies with harmonic current standard in EN.
61000-3-2 (50-W to 240-W models).
The top class in industry for compact size.
Boost current output (some models excluded).

Power rating: 350 W.
Input voltage: 100 to 120 VAC, 200 to 240 VAC (allowable range: 90 to 132 VAC,
180 to 264 VAC, or 254 to 373 VDC(Select with the switch.)*2).
Output voltage: 5 V VDC.
Output current: 60 A.
Built-in fan: Yes.
Model with terminal block facing forward.
High Reliability at a Reasonable Cost OMRON S8EX-P10005L.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation S8EX-P10005L
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage.
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life. A reliable 3-year warranty.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications OMRON S8EX-P10005L.
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W. Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control OMRON S8EX-P10005L.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF controol, phase control, and cyclic control S8EX-P10005L.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads S8EX-P10005L.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).