Input voltage: 24 VDC (24 to 28 VDC).
Output voltage(during backup operation): 22.5 V.
Output current: 2.5 A.
and Other Problems Resulting from Momentary.
Power Failures.
Provides a backup time of 500 ms at an output current of 2.5 A.
Can be wired to the 24-V output from the S8VS Supplies.
Connects to an S8TS Power Supply via an S8T-BUS03 Bus Line Connector.
the backup time and current capacities.
Complies with SEMI F47-0200 standard.
RoHS-compliant.
Ambient operating temperature range of –20 to 60°C.
Socket body.
Representative examples of applicable models.
Timer: H3Y series; H3YN series; H3Y (N) -2-B.
Pole number: 2.
Socket for MY relay, G2R-S relay.
Save hours of Push-InPlus terminal type to add product series.
Using Plus Push-In terminal, compared with the previous screw terminals,
Save wiring time (compared with the previous screw terminals, can shorten the wiring time of about 60%*) OMRON S8T-DCBU-02
S8T-DCBU-02
Screw will not loose, to achieve maintenance free.
The insertion force is small, the drawing strength is big, and the wiring time is saved, and the high reliability is simultaneously considered.
When connecting multiple strands, the use of non - holding mechanism,
Insert a word screwdriver to keep it OMRON S8T-DCBU-02.
2 wires can be inserted in each terminal.
DIN guide rail installation, screw mounting common. Type: With cable.
Connector: Connectors on both cable ends.
DC: Cable length L, 3 m; Minimum order, 5.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime OMRON S8T-DCBU-02.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Type: Normal wiring.
Cable length L: 0.5 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Detect abnormal voltages applies to equipment to,
protect against equipment failure.
Monitor for overvoltages and undervoltages,
simultaneously with one Relay.
Monitor AC or DC voltages with one Relay.
Settings for the operating value, hysteresis, and operating time S8T-DCBU-02.
Width of 17.5 mm to reduce space required in panels.
Push-In Plus Terminal that reduce wiring work.
The use of cage clamps enables wiring with bare stranded wires.
Double-insertion holes for crrossover wiring (all terminals) S8T-DCBU-02.
UL listed for easy shipping to North America.
Models added with transistor outputs for superior contact reliability.