LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
SAO-R1N | OMRON Current Sensor SAO-R1N
OMRON SAO-R1N Manual And Instructions
SAO-R1N datasheetPDF datasheet
SAO-R1N Installation and Operating Manual

OMRON SAO-R1N Product information and technical parameters:
Brand: OMRON
Name: Current Sensor
Model: SAO-R1N
Terminal/mounting: Plug-in/DIN rail via socket.
Control voltage: 100/110/120 VAC.
Overcurrent detection: Inverse type.
Solid-state, Plug-in Current Sensor.
Applicable to motor overcurrent protection and 3-phase AC current detection.
Inverse-type, start-up lock type, and instantaneous type over,
current sensors available.
Instantaneous type under current sensor available.
Plug-in design simplifies installation, removal, and wiring.
DIN sized (48 mm x 96 mm).

Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element OMRON SAO-R1N.
Burnout Detector compatible with a,
wide-range of heater control methods SAO-R1N
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance OMRON SAO-R1N.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Category: incidental cover type.
Structure: DIN guide rail mounting type.
Capacity: 30W.
Output voltage: 12V.
Output current: 2.5A OMRON SAO-R1N.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminaals)
Support finger touch protection to prevent electric shock SAO-R1N.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer SAO-R1N. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"



...More relevant models >>>>
Last one: OMRON SAO Series
next one: OMRON SAO-R2N