SRT2-OD08 | OMRON Transistor Remote I/O Terminals SRT2-OD08
OMRON SRT2-OD08 Manual And Instructions
SRT2-OD08 datasheetPDF datasheet
SRT2-OD08 SETUP MANUAL

OMRON SRT2-OD08 Product information and technical parameters:
Brand: OMRON
Name: Transistor Remote I/O Terminals
Model: SRT2-OD08
I/O classification: Output.
Internal I/O circuit common: NPN (- common).
I/O points: 8.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Long-distance Communications Supported by SRT2 Models,
(Long-distance/High-speed Communications Selection).
Ultra-compact at 80 x 48 x 50 (W x H x D) mm for,
4-point and 8-point terminals and 105 x 48 x 50,
(W x H x D) mm for 16-point terminals.
Two independent power supplies can be used,
because the I/O terminals are insulated from the internal circuits.
DIN track mounting and screw mounting are both supported.

Name: Slice I/O Units; Digital I/O Units.
Specifications: 8 outputs NPN.
Standards: CE, UC1, L.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON SRT2-OD08.
A wide variety of CompoNet Slave Units,
contribute to system size reduction SRT2-OD08
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: Screw Terminal Block with Relay Outputs.
Specifications: Outputs;
16 outputs; Contacts OMRON SRT2-OD08.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error OMRON SRT2-OD08. Name: Analog I/O Slave Units.
Specifications: Analog outputs;
2 outputs.
Standards: CE, U, U1, C, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Input/Output: Inputs.
Internal I/O circuit common: PNP (– common).
I/O points: 8 points.
I/O connection method: Sensor connector.
Rated voltage for I/O power supply: 24 VDC.
Eight Waterproof Terminal Models.
Emphasizing Cost Efficiency.
Reduced Labor.
Connection using connectors reduces the lead time,
required for installation. No tools are required for,
connection to a variety of devices.
Reduced Wiring.
Signal line wiring has been reduced so that the,
Terminal can be mounted closer to sensors and,
other devices.
Relay Box not Required.
Environment-resistant, dust-tight, drip--proof,
construction (IP67) enables direct on-site,
mounting SRT2-OD08.
Easier Maintenance.
Significant reductions not only in setup time but also,
maintenance time.
Reduced Space, Improved Operability,
Compact design (160 x 54 mm (W x H)) (88-point models) SRT2-OD08.
Settings and connections can be performed using,
the switch and connectors on the front side of the Terminal.
System Configuration.