SRT2-OD16P | OMRON Remote I/O Modules SRT2-OD16P
OMRON SRT2-OD16P Manual And Instructions
SRT2-OD16P datasheetPDF datasheet
SRT2-OD16P HOST CONNECTION MANUAL

OMRON SRT2-OD16P Product information and technical parameters:
Brand: OMRON
Name: Remote I/O Modules
Model: SRT2-OD16P
I/O classification: Output.
Internal I/O circuit common: NPN (– common).
I/O points: 16.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Module Type that Allows PCB Mounting.
Compact size at 60 x 16 x 35 (W x H x D).
Lineup now includes the 16-point input model and,
16-point output model.

Name: Expansion Units.
Specifications: Outputs;
8 outputs; NPN;
One Expansion Unit can be,
mounted to one CRT1-ID16(-1),
CRT1-OD16(-1), CRT1-ROS16,
or CRT1-ROF16 Digital I/O Slave.
Standards: CE, UC, UC1, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet OMRON SRT2-OD16P.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system SRT2-OD16P
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error OMRON SRT2-OD16P. Classification: For input.
Internal I/O circuit common: NPN (– common).
I/O points: 8 input points.
Connector Connection Models that.
Allows Easy Connection to Sensors and Output Devices.
Sensors with easy-to-wire connectors are easily,
attached or detached.
Connects to 2-wire sensors.
Remote teaching of the Sensor Terminal is possible.
with the PLC by using output signals of the Sensor Terminal OMRON SRT2-OD16P.
DIN track mounting and screw mounting are available. Specifications: I/O;
PNP (input: - common, output: + common);
Input: 8 points/Output: 8 points.
I/O connections: M3 Screw terminals.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Allows I/O Expansion with Transistor Terminals.
Wide variety of data, such as maintenance system data,
can be collected without affecting the prodductivity,
of the control system SRT2-OD16P.
Valuable information can be collected,
and managed through the network, including information,
on the communications power supply.
voltage levels, Unit wear and tear,
and equipment operating informattion SRT2-OD16P.
Expansion via Expansion I/O Units.
With no communications baud rate settings,
required and detachable terminal blocks,
maintenance is easier.