Suitable cable dia: 3 mm dia. model (3 to 4 mm dia.).
Suitable core size: 0.5 max.
Suitable Sheath material: PVC, PE, PUR.
Cable connection direction: Straight.
Connection method: Soldering.
AC: Model.
Minimum order: 50.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
94V-0 fire retardant rating.
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.
Cable Specifications: Fire-retardant, Robot cable.
Cable connection direction: L-shaped.
Cable diameter: 6.0 mm dia.
No. of cable cores: 2.
Cable core cross sectional area: 0.5 mm.
Cable length: 1 m.
DC.
Minimum order: 10.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort OMRON XS2C-A425.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating
XS2C-A425
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified OMRON XS2C-A425.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Setting range: 0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC, 0.8 to 8 A AC/DC.
Power supply voltage: 100 to 240 VAC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents or undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A).
Manual resetting and automatically resetting supported by one Relay OMRON XS2C-A425.
Startup lock and operating time can be set separately.
One SPDT output relay, 5 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Suitable cable dia: 6 mm dia. model (5 to 6 mm dia.).
Suitable core size: 0.5 max.
Suitable Sheath material: PVC, PE, PUR.
Cable connection direction: L-shaped.
Connection method: Soldering.
AC: Model.
Minimum order: 50.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirementts and ensure a,
94V-0 fire retardant rating XS2C-A425.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of CConnector Assembly: Crimping, soldering, and screw-on XS2C-A425.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.