Suitable cable dia: 3 mm dia. model (3 to 4 mm dia.).
Suitable core size: 0.18 to 0.3mm; 0.5 to 0.75mm.
Suitable Sheath material: PVC, PE, PUR.
Cable connection direction: L-shaped.
Connection method: Crimping.
DC: Model.
Minimum order: 50.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
94V-0 fire retardant rating.
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.
Control power supply voltage: 200/220 VAC.
Input: DC or AC (selectable), Input voltage range, 0.2 to 12 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL) OMRON XS2C-D4C6.
Detect three-phase AC current for under and/or overcur,
rent using current converter
XS2C-D4C6
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F) OMRON XS2C-D4C6.
LED operation indicator.
UL/CSA approval (SDV-F@). Rated voltage: 115 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2300 r/min; 60 Hz, 2600 r/min.
Maximum flow rate: 50 Hz, 1.6 m3/min; 60 Hz, 1.9 m3/min.
Maximum static pressure: 50 Hz, 41 Pa; 60 Hz, 43 Pa OMRON XS2C-D4C6.
Noise: 50 Hz, 44 dB; 60 Hz, 47 dB.
Weight: Approx. 2260 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting.
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades. Suitable cable dia: 6 mm dia. model (5 to 6 mm dia.).
Suitable core size: 0.18 to 0.3mm; 0.5 to 0.75mm.
Suitable Sheath material: PVC, PE, PUR.
Cable connection direction: L-shaped.
Connection method: Crimping.
AC: Model.
Minimum order: 50.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirementts and ensure a,
94V-0 fire retardant rating XS2C-D4C6.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of CConnector Assembly: Crimping, soldering, and screw-on XS2C-D4C6.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.