No. of cable cores: 4.
Cable connection direction: Straight.
Cable length L: 1 m.
Small Round Water-resistive.
Connectors.
Water-resistive, compact connector meets IP67 requirements.
S8 snap-in models that connect and disconnect with one touch.
Ideal for a wide variety of FA and OA applications.
Connectors on both cable ends require no harness work.
Some new M8 models with 3 or 5 poles.
Detect errors in motors and other equipment,
through current changes.
Use in either overcurrent or undercurrent mode.
Monitor AC or DC currents with one Relay.
Use with commercially available CTs (CT secondary side: 0 to 1 A or 0 to 5 A).
Settings for the operating value, hysteresis, startup lock time,
and operating time OMRON XS3H-S421-401-R.
Width of 17.5 mm to reduce space required in panels
XS3H-S421-401-R
Push-In Plus Terminal that reduce wiring work.
The use of cage clamps enables wiring with bare stranded wires.
Double-insertion holes for crossover wiring (all terminals).
UL listed for easy shipping to North America.
Models added with transistor outputs for superior contact reliability. Time specification: Inverse type OMRON XS3H-S421-401-R.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button OMRON XS3H-S421-401-R.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Ideal for Monitoring 3-phase Power.
Supplies for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor overvoltages, undervoltages, phase sequence,
and phase loss for three-phase 3-wire or 4-wire power,
supplies with just one Unit XS3H-S421-401-R.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply.
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Output overvoltages and undervooltages using separate relays XS3H-S421-401-R.
World-wide power specifications supported by one Unit (switchable).
Output status can be monitored using LED indicator.