Cable specifications: Spatter-resistant Cable.
Cable length L: 2 m.
Cable outer diameter: 6.6 mm.
Straight Connectors.
Minimum order: 5.
UL: --.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved.
Measuring voltage: 20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC.
Supply voltage: 24 VAC/DC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 6 A at 250 VAC (resistive load) OMRON XS5F-D421-D80-SA.
Output relay can be switched between normally open and normally closed
XS5F-D421-D80-SA
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Sensor type and wiring: 3-wire DC PNP/2-wire DC 1-4.
Actuator wiring: Actuator wiring 3-4 OMRON XS5F-D421-D80-SA.
No. of ports: 4.
No. of I/O: 8.
Simple Wiring of Sensor Actuators.
Greatly reduce wiring in combination with the Smartclick XS5.
Insert the connector and turn 1/8 of a turn to lock the connectors.
Higher rated current to enable output applications.
Use previous M12 screw connectors. Category: incidental cover with under voltage detection function.
Structure: bottom mounting type OMRON XS5F-D421-D80-SA.
Capacity: 30W.
Output voltage: 24V.
Output current: 0.65A.
Alarm output: -.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Suppport finger touch protection to prevent electric shock XS5F-D421-D80-SA.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whenn the fan is replaced by the customer XS5F-D421-D80-SA. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"