LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
XS5H-T421-EM0-K | OMRON Industrial Ethernet Cables XS5H-T421-EM0-K
OMRON XS5H-T421-EM0-K Manual And Instructions
XS5H-T421-EM0-K datasheetPDF datasheet

OMRON XS5H-T421-EM0-K Product information and technical parameters:
Brand: OMRON
Name: Industrial Ethernet Cables
Model: XS5H-T421-EM0-K
Cable type: Standard Cables.
Type: Cable with Plug on One End (M12 Straight) .
Cable length: 3 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks.

Power ratings: 480 W.
Input voltage: 100 to 240 VAC.
Output voltage: 24 V.
Output current: 20 A Peak current 30 A(200 VAC).
Alarm output *2: Sinking/sourcing.
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for OMRON XS5H-T421-EM0-K.
Easy System Commissioning.
New 90-W models with indication monitor that XS5H-T421-EM0-K
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC OMRON XS5H-T421-EM0-K.
(Not compliant with EC Directives and other safety standards.) Cable length L: A, 15.0 m; B, 14.75 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC OMRON XS5H-T421-EM0-K.
(DC power cannot be input.).
Power ratings: 50 W.
Output voltage: 5 V.
Output current: 10 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V).
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 508/60950-1, cUL CSA C22.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
Input conditions: The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.).Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 400/440 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indiccated from the start of operation XS5H-T421-EM0-K.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions XS5H-T421-EM0-K. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.


...More relevant models >>>>