Cable specifications: Oil-resistant Polyure thane Cable.
Cable length L: 5 m.
Cable outer diameter: 6 mm.
Straight/straight.
Minimum order: 5.
UL: --.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved.
Type: S8JC-Z series models list.
Meet the criteria: No.
Configuration: power supply with cover; bottom surface mounting.
Input voltage: 200 ~ 240VAC.
Rated power: 15W.
Output voltage: 24VDC.
Output current: 0.7A.
Economic type power supply S8JC-Z additional models,
The new power S8JC-ZS has a CE certification mark to market OMRON XS5W-D421-G81-P.
Product features: reduce material costs;
Export machinery to be used to meet specific safety standards;
Through the DIN guide rail installation, significant savings in time
XS5W-D421-G81-P DC Backup Block for S8TS Prevents 24-VDC.
Outages Due to Power Interruptions or Failures.
Supplies 24 VDC for a fixed period of time even during.
AC input outages to considerably improve system reliability OMRON XS5W-D421-G81-P.
Block Power Supply Basic Block is connected using a Bus Line.
Connector to achieve a simple system configuration.
Notification of alarms is provided by indications on the main unit.
and alarm signal output.
RoHS-Compliant. Control supply voltage: 220 VAC; With voltage fluctuation compensation.
Operating current: 32 to 80 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities OMRON XS5W-D421-G81-P.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Rated voltage: 100 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2700 r/min; 60 Hz, 3100 r/min.
Maximum flow rate: 50 Hz, 2.6 m3/min; 60 Hz, 3.0 m3/min.
Maximum static pressure: 50 Hz, 86 Pa; 60 Hz, 48 Pa.
Noise: 50 Hz, 55 dB; 60 Hz, 56 dB.
Weight: Approx. 2220 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting.
Mounts in a square cutout and conceals the hole-cut tto,
simplify installation work XS5W-D421-G81-P.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and VVent Attachment XS5W-D421-G81-P.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades.