Cable type: Standard Cables.
Type: Cable with Plugs on Both Ends (M12 Straight/RJ45) .
Cable length: 10 m.
Ethernet Networks.
Sensor type: 2 wire DC type 1 - 4 / 3 - 4 non polarity.
Input points: 6.
The I/O sensor connector for centralized wiring,
And the province of the number of processes, strong environmental resistance as the goal,
The outer control relay box.
Compact and strong centralized wiring trunk box conforming to IP67 OMRON XS5W-T421-JMC-K.
The corresponding sensing I/O connector mode proximity switch, limit switch,
Photoelectric switch
XS5W-T421-JMC-K
With the power to show LED, action shows LED.
The installation dimensions are the same and are not related to the number of input points,
Therefore, the addition of a simple exchange.
A series of sensors with self diagnostic features are added to the product. Shape: DIP straight terminal.
Pole number: 10 OMRON XS5W-T421-JMC-K.
Pole pole number: 0.
Minimum packing unit: 90.
Printed board connector core, MIL specification standard.
Through the use of new productivity design, high reliability and low price synchronization.
A box type plug (XG4C) which is convenient for saving space is provided in the province.
A press type plug (XG4E) capable of using the relay is provided.
Will be the company''s loose wire connector (XG5) - specific plug (XG8) and PCB type OMRON XS5W-T421-JMC-K.
(XG2) combined use of various types of packaging can be achieved.
Suitable for the company''s own development of a simple locking lever can make the unique plug (XG8) and,
Box type plugs (XG4C) can also be locked.
MIL specification (MIL-C-83503) standard.
Standard product conforms to the UL specification (No. E103202 File) certified products. Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 400/440 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indiccated from the start of operation XS5W-T421-JMC-K.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions XS5W-T421-JMC-K. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.