LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
XS5W-T422-BM2-K | OMRON Industrial Ethernet Cables XS5W-T422-BM2-K
OMRON XS5W-T422-BM2-K Manual And Instructions
XS5W-T422-BM2-K datasheetPDF datasheet

OMRON XS5W-T422-BM2-K Product information and technical parameters:
Brand: OMRON
Name: Industrial Ethernet Cables
Model: XS5W-T422-BM2-K
Cable type: Standard Cables.
Type: Cable with Plugs on Both Ends (M12 Right-angle/M12 Right-angle).
Cable length: 0.5 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks.

Power supply voltage: 100 to 240 VAC.
Output: Relay.
Timer function: Yes.
Features: Multi-function with two inputs/one output.
Offers High-speed Input Response of,
0.1 ms and Equipped with Built-in Timer,
High-speed response of 0.1 ms.
Ideal as a two-input Controller.
Lineup includes the S3D2-BK with flip-flop functions convenient for,
level control, the S3D2-AKD/CKD/CCD with 24-V power supply, and,
the S3D2-DK/EK with one input/output OFF-delay (two circuits),
useful for load control and lamp display,
Power source for the Sensor can be supplied up to 200 mA OMRON XS5W-T422-BM2-K XS5W-T422-BM2-K
Ultra-slim body with 30-mm width.
Multi-function model equipped with timer functions also available. Open circuit: voltage, no voltage, DC circuit breaker OMRON XS5W-T422-BM2-K.
Appearance: R2 shell, also has F4 shell.
Rated current: AC110V.
Rated frequency: 50/60Hz.
Consume VA: action time 10VA below (except for reactor part).
Action current adjustment range (zero phase converter primary current):
0.1-0.2-0.3-0.4-0.6A (5 shunt).
Control output: -.
Relay control output for switching circuit breakers: power through capacity, C110V/10A;
Switch capacity: AC110V/10A (COS =1) OMRON XS5W-T422-BM2-K.
Quality: about 2kg.
External: Mount Searl N1.5.
High voltage grounding relay AGF type, anti wave interference,
Arc grounding, short circuit capability, high reliability.
The anti - interference ability is strong, and can safely correspond to the arc grounding fault.
The grounding relay and the zero phase converter ZCT can be separately used.
(any combination is not more than JIS of the specified error range, and therefore can be used)
Can carry out fine current adjustment, easy to coordinate.
In all the models set up alarm terminal.
Control power supply voltage: 24 VDC.
Input: DC or AC (selectable), Input voltage range, 0.2 to 12 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
AAvailable in 7 supply voltage configurations XS5W-T422-BM2-K.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrse current detection XS5W-T422-BM2-K.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).


...More relevant models >>>>