Type: Normal wiring.
Cable length L: 0.5 m.
Controllers with one touch.
Terminal/mounting: Plug-in/DIN rail via socket.
Control voltage: 100/110 VDC.
Overcurrent detection: Instantaneous type, W/o start-up lock.
Solid-state, Plug-in Current Sensor.
Applicable to motor overcurrent protection and 3-phase AC current detection.
Inverse-type, start-up lock type, and instantaneous type over,
current sensors available OMRON XW2Z-050BU.
Instantaneous type under current sensor available
XW2Z-050BU
Plug-in design simplifies installation, removal, and wiring.
DIN sized (48 mm x 96 mm). Input voltage: 400 ~ 500 VAC3 phase.
Rated power: 240W.
Output voltage: 24V.
Output current: 10A.
DIN guide rail installation, with 5 A ~ 40 A output current of the power supply.
3 phase 400 ~ 500 VAC.
5, 10, 20 and 40 A; 24 VDC output OMRON XW2Z-050BU.
High stability, low ripple and low noise level.
Compact design.
Add fuse protection.
Natural draft。
In addition to the CE tag, but also in compliance with UL60950 (CSA22.2-60950), UL508.
Conform to EN61000-3-2.
Parallel / series operation. Power ratings: 90 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 3 OMRON XW2Z-050BU. 75 A.
Alarm output *2: Sinking.
UL Class 2 Output standards: Yes.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation XW2Z-050BU.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions XW2Z-050BU. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.