Cable length L: 3.0 m.
Controllers with one touch.
Shape: DIP straight terminal.
Pole number: 10.
Pole pole number: 0.
Minimum packing unit: 90.
Printed board connector core, MIL specification standard.
Through the use of new productivity design, high reliability and low price synchronization.
A box type plug (XG4C) which is convenient for saving space is provided in the province OMRON XW2Z-300X.
A press type plug (XG4E) capable of using the relay is provided
XW2Z-300X
Will be the company''s loose wire connector (XG5) - specific plug (XG8) and PCB type.
(XG2) combined use of various types of packaging can be achieved.
Suitable for the company''s own development of a simple locking lever can make the unique plug (XG8) and,
Box type plugs (XG4C) can also be locked.
MIL specification (MIL-C-83503) standard OMRON XW2Z-300X.
Standard product conforms to the UL specification (No. E103202 File) certified products. Power ratings: 120 W.
Rated input voltage: 100 to 240 VAC .
(allowable range: 85 to 264 VAC or 90 to 350 VDC).
Rated output voltage: 24 V.
Rated output current: 5 A.
Maximum boost current: 6 A.
A Perfect Fit for Small Control Panels.
Coated PCBs for Better Resistance to Environment OMRON XW2Z-300X.
Connections for Easy Wiring.
Operation possible at ambient temperatures from -40 to 70°C.
DC input supported (90 to 350 VDC).
Power Boost function at 120%.
Horizontal side-by-side mounting.
Vibration resistance to 5G, and 300-VAC abnormal,
input voltage supported for 1 second.
Complies with EN/IEC 61558-2-16.
UL 508 Listing/UL 1310 Class 2 output standards *1,
ANSl/ISA 12.12.01.
Certification for 3,000 m altitude,
(UL/EN/IEC 60950-1 and EN 50178).
Lloyd’s, DNV GL *2.
Conforms to F47-0706.
Five years Warranty *3. Control power supply voltage: 125 VDC.
Input: DC, Input voltage range, 0.2 to 12 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current convertter XW2Z-300X.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrse current detection XW2Z-300X.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).