(one ferrite core provided, 30-dia × 39 mm).
Cable length: 10 m.
The highest level of ionization in its class.
Sensing and variable-AC system provides fast and meticulous ionization.
Linked Ionizers cover a wide area without causing uneven ionization.
Digital ion display provides simple and reliable settings.
Rated voltage: 200 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.080 A; 60 Hz, 0.060 A .
Rated input: 50 Hz, 10 W ; 60 Hz, 9 W .
Rated rotational speed: 50 Hz, 2700 r/min; 60 Hz, 3200 r/min.
Maximum flow rate: 50 Hz, 0.8 m3/min; 60 Hz, 0 OMRON ZJ-BAS-MC10B. 9 m3/min.
Maximum static pressure: 50 Hz, 42.1 Pa; 60 Hz, 58.8 Pa.
Noise: 50 Hz, 32 dB; 60 Hz, 36 dB
ZJ-BAS-MC10B
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series OMRON ZJ-BAS-MC10B.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Cable with connector (1 to 1) /G79-I_C, G79-O_C.
L size: 500mm OMRON ZJ-BAS-MC10B.
Input use
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is inndicated from the start of operation ZJ-BAS-MC10B.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions ZJ-BAS-MC10B. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.