Type: Used for connecting Ionizers.
Cable length: 1,750 mm.
The highest level of ionization in its class.
Sensing and variable-AC system provides fast and meticulous ionization.
Linked Ionizers cover a wide area without causing uneven ionization.
Digital ion display provides simple and reliable settings.
Square socket.
Equipped with a wide variety of square and round sockets,
Surface connection and back connection.
With a finger touch protection type.
With the fixed bracket, PYF cross tab.
Add no screw series. Power ratings: 120 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*1) OMRON ZJ-BAS-MC17RB.
Output voltage: 24 V.
Output current: 5 A.
Alarm output *2: Sinking
ZJ-BAS-MC17RB
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor OMRON ZJ-BAS-MC17RB.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Product: Replacement Dischargers (set of 5).
Wide Range of Nozzles for Optimal OMRON ZJ-BAS-MC17RB.
Ionization.
A wide range of nozzle variations.
High-frequency AC method with excellent ion balance. Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily becausee operation time,
is indicated from the start of operation ZJ-BAS-MC17RB.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeency, basic,
frequency, and load conditions ZJ-BAS-MC17RB. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,