ZN-CTM51-200A | OMRON New-generation environmental sensor ZN-CTM51-200A
OMRON ZN-CTM51-200A Manual And Instructions
ZN-CTM51-200A datasheetPDF datasheet
ZN-CTM51-200A User's Manual

OMRON ZN-CTM51-200A Product information and technical parameters:
Brand: OMRON
Name: New-generation environmental sensor
Model: ZN-CTM51-200A
Product name: Clamp type CT, Connector: For connecting the branch cable,
Cable length: 0.2 m.
Power supply: Battery/DC cable.
Easy and Quick "Checking Power"at the Worksite.

Cable length: 3 m.
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously OMRON ZN-CTM51-200A.
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit ZN-CTM51-200A
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power OMRON ZN-CTM51-200A.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settings OMRON ZN-CTM51-200A.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection. Category: ontology; power monitoring.
Application circuit: single phase 2 wire; single phase 3 wire; three-phase 3 wire.
Supply voltage: AC100 ~ 240V (50/60Hz).
Output function: open collector output; cumulative output pulse output; alarm output.
Communication specifications: RS-485.
Memory card function: No.
Simple monitoring of the use of electricity to support energy saving countermeasures.
On behalf of the use of the mechanical equipment, the measurrement of the initial voltage, current,
Cumulative quantity, invalid power, power factor, frequency ZN-CTM51-200A.
To achieve a simple record with a memory card. (with memory card function model)
The measurement data can be stored in the main body, and the centralized monitoring and management can be carried out in the communication network ZN-CTM51-200A.
Wide 45mm miniaturization, simple set to the DIN guide.