Name: SYSMAC LINK Module.
Model: C200HW-SLK24.
Communications method: N: N token bus.
Transmission method: Manchester code, base band.
Transmission path: Bus.
Weight: 400 g max.Specification: Platinum resistance thermometer input (Pt100, JPt100),
heater burnout alarm,
manual operation,
ON/OFF or advanced PID control,
transistor (PNP) output, 2 loops CP1E-N20DR-A REFERENCE MANUAL. For Hand-held Programming Console
CP1E-N20DR-A
2m.Product name: N@@-type CPU Units with 30 I/O Points.
Specifications: Power Supply, 24 VDC; Inputs, 18; Outputs, 12;
Output type: Transistor (sinking).
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.27A; 24 V,0.02A.
Standards: UC1, N, L, CE CP1E-N20DR-A REFERENCE MANUAL.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Model: C200H-IA221.
No. of inputs: 8 pts.
Input voltage: 200 to 240 VAC, +10%/–15% CP1E-N20DR-A REFERENCE MANUAL.
Input current: 10mA, 200VAC.
Isolation: Photo-coupler.
Indica-tor: LED.
External connec-tions: Remove-able termi-nal blocks.
Inputs percom-mon: 8 pts.
Internal currentcon-sump-tion: Unit type: CJ1 Basic I/O Units.
Product name: Quick-response Input Unit.
Specifications: I/O points, 16 inputs;
Input voltage current, 24VDC, 7mA;
Commons: 16 points, 1 common;
Input pulse widt conditions, ON time:
0.05 ms max. OFF time: 0.5 ms max;
Max. Units mountable per Unit, 2;
External connection, Removable terminal block.
No. of words allocated: 1 word.
Current consumption: 5V, 0.08A; 24V, --.
Standards: UC1, N, L, CE.
Capture Input Signals Shorter,
Than the Cycle Time.
This Input Unit can read pulse inputs that,
are shorter than the cycle time of the CPU Unit. Unit classification: CJ1 Special I/O Units.
Product name: Process Input Units,
(Isolated type Units with Universal Inputs).
Input points: 4 inputs.
Signal range selection:
Set separately for each input.
Signal range:Fully universal
inputs: Pt100, JPt100, Pt1000, K,
J, T, L, R, S, B, 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, 0 to 10 V.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs.
Accuracy at ambient temperature of 25°C:
Accuracy: Platinum resistance thermometer,
input: ±0.3% of PV or ±0.8°C, whichever,
is larger) ±1 digit max. Thermocouple input:
(±0.3% of PV or ±1.5°C, whichever is larger),
±1 digit max. *1 Voltage or current input:
±0.3% of F.S. ±1 digit max.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Currrent consumption: 5V, 0 CP1E-N20DR-A Manual. 32A; 24V, --.
Standards: UC1, L, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four inpuut channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) CP1E-N20DR-A Manual.
All inputs are isolated.