Name: Position Control Module.
Model: C200HW-NC213.
Control method: Open-loop, automatic trapezoid acceleration/deceleration.
Control output sig-nals: Pulse-train outputs.
Controlled axes: 2.Name: Two-tier Screw Terminal Block.
Specifications: Inputs; 8 inputs; PNP.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet CP1E-NA20DR-A USER'S MANUAL.
Branching is easily made with CompoNet
CP1E-NA20DR-A
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error CP1E-NA20DR-A USER'S MANUAL. C500-AD/3G2A5-AD Special I/O Unit Analog Input C500-AD006(3G2A5-AD006).
Input: 4 pts.
Specification: +1~+5V、4~20mA.Name: Controller Link Module.
Model: C200HW-CLK21.
Communications method: N: N token bus.
Code Manchester: codeName: DC Power Supply Unit.
Power supply voltage: 24 VDC.
Output capacity: 5 VDC output capacity, 4 CP1E-NA20DR-A USER'S MANUAL. 3A;
26 VDC output capacity, 0.56A;
Total, 28W.
Options: 24 V DC service power supply, No;
RUN output, No.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables.
Name: e-CON Connectors.
Specifications: Outputs; 16 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Product name: CS1 CPU Backplane.
Specifications: For both CS/C200H-series Units,
Units cannot be mounted; 3 slots.
Appli cable CPU Unit: CS1 CPU Unit.
Basic I/O Units: CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, Yes;
C200H Group--2 High density I/O Unit, Yes CP1E-NA20DR-A Communications Commands Manual.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, Yes.
CPU Bus Units: CS-series CPU Bus Unit, Yes.
Current consumption: 5V system, 0.111A;
26 V system, -- CP1E-NA20DR-A Communications Commands Manual.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control.