Product name: CS1 CPU Backplane.
Units cannot be mounted; 8 slots.
Appli cable CPU Unit: CS1 CPU Unit.
C200H Group-2 High density I/O Unit, No.
Yes; C200H series Special I/O Unit, No.
CPU Bus Units: CS-series CPU Bus Unit, Yes.
26 V system, --.
Standards: U, C, N, L, CE.
Highly Reliable Process Control.
Unit type: CS1 Special analog I/O Units.
Product name: Analog I/O Units.
Specifications: I/O points,
4 inputs, 4 outputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/4000 ;
Conversion speed, 1 s/point OMRON CS1W-BC082.
Externa connection, Removable erminal block.
Current consumption: 5V, 0
CS1W-BC08220A; 26V, 0.20A.
Standards: UC1, N, L, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data.
Analog Output Units for converting ,
binary data into analog output signals. Unit classifi cation: CS1 CPU Bus Unit.
Product name:Controller Link Unit.
Specifications: Communications cable,
Optical ring GI cabl;
Communications type, Data links and,
message service; Duplex support,
Yes OMRON CS1W-BC082. Unit duplexing and cable loop,
back are supported.
Max. Units mountable per CPU Unit,
Non-duplex: 8, Duplex: 11 (6 Units,
comprising 3 sets of Duplex Units,
+ 5 Non-duplex Units).
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.65A; 26V, --.
Standards: UC1, N, L, CE OMRON CS1W-BC082.
New Controller Link Units,
Now with 4,000 Send Words.
The Controller Link is an,
FA network that can send,
and receive large amounts,
of data easily and at high speed.
The Controller Link supports data,
links that enable sharing data between,
PLCs and computers and a message service,
that enables sending and receiving,
data whenever required.
With Wired Controller Link Units,
systems can be flexibly built by using,
Repeater Units to enable T branches,
long-distance wiring, and converting,
part of the network to optical cable. Specifications: Two RS-422A/485 ports.Meet the standard interface IEEE-488-1978 (GP-IB).Type: Counter inputs, pulse outputs.
12 DC inputs: Yes.
Counter inputs: 2.
Analog inputs: None.
8 transistor outputs: Yes.
2 pulse outputs: Yes.
2 analog outputs: No.Name: I/O Control Unit.
Specifications: Applicaable systems,
Duplex CPU, Dual I/O Expansion System only;
Duplexing, Supported;
Online Replacement, Supported;
Mounting Backplane, Expansion Backplane;
Connecting Cable, CS1W-CN@@3,
CS-series Connecting Cable CS1W-BC082.
Current consumption: 5V system, 0 CS1W-BC082. 20A;
26V system, --.
Standards: UC1, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables.