LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
E5EN-C3BBFT-N | OMRON Foundation type temperature controller E5EN-C3BBFT-N
OMRON E5EN-C3BBFT-N Manual And Instructions
E5EN-C3BBFT-N datasheetPDF datasheet
E5EN-C3BBFT-N datasheetPDF datasheet
E5EN-C3BBFT-N datasheetPDF datasheet
E5EN-C3BBFT-N Basic TypeBasic Type
E5EN-C3BBFT-N User's Manual
E5EN-C3BBFT-N User's Manual
E5EN-C3BBFT-N User's Manual
E5EN-C3BBFT-N Communications FunctionsUser's Manual
E5EN-C3BBFT-N INSTRUCTION Manual
E5EN-C3BBFT-N INSTRUCTION Manual

OMRON E5EN-C3BBFT-N Product information and technical parameters:
Brand: OMRON
Name: Foundation type temperature controller
Model: E5EN-C3BBFT-N
Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 4.
Transfer output: output (special terminal).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.

Size: 48 x 48mm.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Auxiliary output: 2 independent points.
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: - OMRON E5EN-C3BBFT-N.
Communication: RS-485.
Event input: 2 points.
Remote SP input: - E5EN-C3BBFT-N
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms OMRON E5EN-C3BBFT-N.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately) OMRON E5EN-C3BBFT-N.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication. Case color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: Transfer output using control output.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5EN-C3BBFT-N.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5EN-C3BBFT-N.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.


...More relevant models >>>>