Outputs: Time-limit contact and instantaneous contact .
Supply voltage: 110 VAC (50/60 Hz); 220 VAC (50/60 Hz).
transfer time range (up to 1.0 seconds).
and to limit the setting range.
Panel Covers (order separately) to enable various panel designs.
Approved by UL, CSA, CE and CCC.
Highly Visible LCD Display with 2-color,
(Red and Green) LEDs.
Multi-range DC voltage/current input.
Front-panel key operation for easy setting.
Average processing function suppresses flicker.
Scaling, front-panel forced-zero, zero-limit functions.
Easy confirmation of max/min display.
Short 80-mm depth (measured from edge of face plate) OMRON H3BG-N8H.
Finger protective cover (standard equipment) guards against electric shock
H3BG-N8H
Water- and dust-proof NEMA4X (IP66 equivalent) front panel.
Recognized to U.S. and Canadian requirements under the Component,
Recognition Program of UL.
CE marking. Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with OMRON H3BG-N8H.
No output: -.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the color, can switch the green / Red 2 kinds of color display OMRON H3BG-N8H.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Can enter DC0.001mV toDIN 48 X 48-mm Power OFF-delay Timer.
Long power OFF-delay times;
S-series: up to 12 seconds,
M-series: up to 12 minutes.
Models with forced-reset input are available.
11-pin and 8-pin models are available. Type: H5CX-L series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 H3BG-N8H.
External connections: 8-pin socket.
Input: Signaal, Reset (NPN input) H3BG-N8H.
Output: Contact output (time-limit SPDT).
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry.