Output type: BCD+ transistor; -; NPN open collector (5 bit output +HH, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
External event input can be applied to a variety of measurement and identification situations.
Input type: DC voltage input type.
Output type: communication; RS-485; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with OMRON K3HB-XAA-BCD1 AC/DC24.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table
K3HB-XAA-BCD1 AC/DC24
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviClassification: Totalizing Counter OMRON K3HB-XAA-BCD1 AC/DC24.
Input signal system (Count & reset inputs): Contact/Transistor.
Mounting method: Flush mounting, surface mounting.
Display: 7-segment LEDs (10 mm high).
Number of digits: 4 digits (0 to 9,999).
Backup power for memory protection: Yes.
Control output: --.
Operating mode: Up counting.
Max.counting speed: 5 kcps (see note 1.).
All Required Counter Functions OMRON K3HB-XAA-BCD1 AC/DC24.
Incorporated in a Compact DIN-sized.
(48 × 48) Housing.
In addition to Up and Down models, a reversible (Up-Down),
counter is also available.
Maximum counting speed of 5,000 cps, never before attained by,
a small-size preset counter.
Power supply freely selectable within a range of 100 to 240 VAC.
Also, power supply for the DC-operated models is selectable,
within a range of 12 to 48 V.
Models with memory backup function against power failure available. Control output: Time-limit SPDT and Instantaneous SPDT.
Supply voltage: 24 VDC.
Solid-state Timer with Single Time Range.
and Operating Mode.
Time range: H3BA-X8HA (0.05 s to 12 h),
H3BA-X8HB (0.3 s to 30 h),
H3BA-X8HC (0.6 s to 60 h).
Operating mode: ON-delay only.
Pin type: 8-pin oonly K3HB-XAA-BCD1 AC/DC24. Input: With reset input.
Output: SPDT.
Supply voltage: 100 to 120 VAC, 200 to 240 VAC, 24 VAC/DC, 48 VDC, 100 to 125 VDC.
8-pin models: S-series, M-series.
DIN 48 X 48-mm Power OFF-delay Timer.
Long power OFF-delay ttimes;
S-series: up to 12 seconds,
M-series: up to 12 minutes K3HB-XAA-BCD1 AC/DC24.
Models with forced-reset input are available.
11-pin and 8-pin models are available.