New Super MK Relays.
Models with Latching Lever Added to the Series.
Same mounting and internal wiring as the previous Super.
MK Relays.
Built-in mechanical indicator enables checking contact operation.
Two modes can be used to check circuits for models with latching lever.
Nameplate provided on models with latching lever.
All materials are RoHS compliant.
UL and IEC (TÜV) certification.
Number of poles: 4 poles.
Classification: Models with single contacts.
Rated voltage: Standard products, 100/110 or 200/220 VAC, 12, 24 or 100/110 VDC;
Made-to-order items, 12, 24, 110/120, or 220/240 VAC, 48 VDC.
New Latching Levers for Circuit Checking.
Added to Our Best-selling.
MY General-purpose Relays OMRON MK-S Series.
Now lead-free to protect the environment.
VDE certification (Germany)
MK-S Series
Different colors of coil tape for AC and,
DC models to more easily distinguish them.
MY(S) models with latching levers added for,
easier circuit checking. Classification: Relay .
Structure: 4 poles.
Contact configuration: DPST-NO/DPST-NC.
Rated Voltage: 12, 24 VDC.
Compact Electromagnetic Contactors That OMRON MK-S Series.
Switch 40 A at 440 VAC.
One pole carries 40 A.
UL 508 and UL 840 NC contacts (resistive 40 A 480 VAC, 60 Hz, 80,000 operations).
EN 60947-4-1 NC contacts (AC1 40 A 440 VAC, 50/60 Hz, 80,000 operations).
Ideal for supply power to industrial inverters, servo drivers, and other devices,
and switching power to motors and other equipment.
The maximum load capacity of 160 A when using 4-pole parallel connections OMRON MK-S Series.
EN 60947-4-1 certification for mirror contact mechanism obtained by combining,
the Relay with an Auxiliary Contact Block.
Conforms to European PV standard (VDE0126).
Approx. 30% less operation noise than a standard electromagnetic contactor.
(Approx. 100 dB reduced to approx. 70 dB.)
Approx. 50% the volume of a standard electromagnetic contactor,
to help downsize control panels.
According to OMRON investigation of IIEC-AC1 50 A specifications. Isolation: Photo-voltage coupler.
Zero cross function: No.
Indicator: Yes.
Rated output load: 0.5 A at 24 to 240 VAC, 0.5 A at 24 to 110 VDC.
Rated input voltage: 5 VDC.
100-A-max. Leakage Current, No Bleeder.
Resistor Required.
1 mA to 500 mA micro-load switching.
Switch to both AC and DC with no polarrity MK-S Series.
Switch for a wide range of voltages; 19.2 to 264 VAC, 19.2 to 125 VDC.
Switch full- and half-wave rectifier AC loads.
Same sizes and terminal arrangements as OMRON Power,
Relay MY Series.
Operating indicator provided.
Switch MY Series (without bleeder resistor) MK-S Series.
Superior surge absorption with a built-in varistor.
Optimum SSR to control minute load, valves, and solenoids.