LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
S8AS-24006R | OMRON Smart Power Supply S8AS-24006R
OMRON S8AS-24006R Manual And Instructions
S8AS-24006R datasheetPDF datasheet
S8AS-24006R USER'S MANUAL
S8AS-24006R Connection Guide

OMRON S8AS-24006R Product information and technical parameters:
Brand: OMRON
Name: Smart Power Supply
Model: S8AS-24006R
Capacity: 240 W.
Input voltage: 100 to 240 VAC.
Output voltage: 24 V.
Maximum cutoff output current (per branch): 3.8 A.
Total output current: 10 A.
Number of output branches: 6 branch outputs.
Communications functions: RS-485.
Parameter settings: Changeable .
A New Type of Power Supply That.
Provides Safety and Maintainability.
240- and 480-W power supplies with and digital circuit,
protectors in a single package.
Each branch output tripping current value can be easily,
set at 0.1-A increments.
Startup and shutdown sequence control included.
Various monitor displays and alarms (output voltage,
output current, maintenance forecast monitor,
temperature).
Conforms to UL Class 2.
Mounts to DIN Rail.

Power rating: 100 W.
Input voltage: 100 to 120 VAC, 200 to 240 VAC (allowable range: 85 to 132 VAC,
176 to 264 VAC, or 248 to 373 VDC(Select with the switch.).
Output voltage: 12 V VDC.
Output current: 8.5 A.
Built-in fan: None.
Model with terminal block facing upward.
High Reliability at a Reasonable Cost OMRON S8AS-24006R.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation S8AS-24006R
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage.
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life. A reliable 3-year warranty.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications OMRON S8AS-24006R.
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W. Time specification: Inverse type.
Current setting range: 2 to 8 A OMRON S8AS-24006R.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is iindicated from the start of operation S8AS-24006R.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions S8AS-24006R. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.


...More relevant models >>>>
Last one: OMRON S8AS-24006N
next one: OMRON S8AS-48008